Literature DB >> 28168587

Improving the quality of reconstructed X-ray CT images of polymer gel dosimeters: zero-scan coupled with adaptive mean filtering.

M B Kakakhel1, A Jirasek2, H Johnston3, T Kairn4,5, J V Trapp6.   

Abstract

This study evaluated the feasibility of combining the 'zero-scan' (ZS) X-ray computed tomography (CT) based polymer gel dosimeter (PGD) readout with adaptive mean (AM) filtering for improving the signal to noise ratio (SNR), and to compare these results with available average scan (AS) X-ray CT readout techniques. NIPAM PGD were manufactured, irradiated with 6 MV photons, CT imaged and processed in Matlab. AM filter for two iterations, with 3 × 3 and 5 × 5 pixels (kernel size), was used in two scenarios (a) the CT images were subjected to AM filtering (pre-processing) and these were further employed to generate AS and ZS gel images, and (b) the AS and ZS images were first reconstructed from the CT images and then AM filtering was carried out (post-processing). SNR was computed in an ROI of 30 × 30 for different pre and post processing cases. Results showed that the ZS technique combined with AM filtering resulted in improved SNR. Using the previously-recommended 25 images for reconstruction the ZS pre-processed protocol can give an increase of 44% and 80% in SNR for 3 × 3 and 5 × 5 kernel sizes respectively. However, post processing using both techniques and filter sizes introduced blur and a reduction in the spatial resolution. Based on this work, it is possible to recommend that the ZS method may be combined with pre-processed AM filtering using appropriate kernel size, to produce a large increase in the SNR of the reconstructed PGD images.

Entities:  

Keywords:  Adaptive mean filtering; Average scan; Gel dosimetry; Radiation therapy; X-ray CT; Zero-scan image

Mesh:

Substances:

Year:  2017        PMID: 28168587     DOI: 10.1007/s13246-017-0523-9

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  3 in total

1.  3-D Gabor-based anisotropic diffusion for speckle noise suppression in dynamic ultrasound images.

Authors:  Haobo Chen; Haohao Xu; Peng Shi; Yuchen Gong; Zhen Qiu; Lei Shi; Qi Zhang
Journal:  Phys Eng Sci Med       Date:  2021-01-26

2.  Flexible Textile-Based Pressure Sensing System Applied in the Operating Room for Pressure Injury Monitoring of Cardiac Operation Patients.

Authors:  De-Fen Shih; Jyh-Liang Wang; Sou-Chih Chao; Yin-Fa Chen; Kuo-Sheng Liu; Yi-Shan Chiang; Chi Wang; Min-Yu Chang; Shu-Ling Yeh; Pao-Hsien Chu; Chao-Sung Lai; Der-Chi Shye; Lun-Hui Ho; Chia-Ming Yang
Journal:  Sensors (Basel)       Date:  2020-08-17       Impact factor: 3.576

3.  Improvement of sensitivity of X-ray CT reading method for polymer gel in radiation therapy.

Authors:  Negin Javaheri; Mehran Yarahmadi; Abdollah Refaei; Ali Aghamohammadi
Journal:  Rep Pract Oncol Radiother       Date:  2019-12-19
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.