Samuel M Rosolina1, Stefanie A Bragg1, Ruizhuo Ouyang1, James Q Chambers1, Zi-Ling Xue1.
Abstract
A pyridine-functionalized thin film has been fabricated to selectively preconcentrate Cr(VI) anions for electrochemical detection in the 5-300 μg L-1 range. Glassy carbon electrodes were modified through physical deposition of single-walled carbon nanotubes (SWNTs) on the electrode surface, followed by electrochemical deposition of a sol-gel containing a 2-pyridine functional group. The use of SWNTs has increased sensitivity for Cr(VI) detection in aqueous solutions, providing a detection limit of 0.8 μg L-1.Entities:
Keywords: chromium detection; glassy carbon electrode; iridescence; single-walled carbon nanotubes; solgel; thin film
Year: 2016 PMID: 28167882 PMCID: PMC5291338 DOI: 10.1016/j.jelechem.2016.08.001
Source DB: PubMed Journal: J Electroanal Chem (Lausanne) ISSN: 1572-6657 Impact factor: 4.464