Optimization of oestradiol assays to improve utility in an in vitro fertilization setting.

M Peavey1, N Akbas2,3, W Gibbons1, P Zarutskie1, S Devaraj2,3.   

Abstract

Background The measurement of oestradiol is an integral component for the management of ovarian stimulation for in vitro fertilization. Automated immunoassays offer fast assay times and high throughput, with less sensitivity and specificity. The aim of this study is to optimize the oestradiol assay in patients undergoing ovarian stimulation for in vitro fertilization via comparison of oestradiol values obtained using two immunoassays compared with mass spectrometry. Methods Patients undergoing ovarian stimulation were prospectively recruited. Serum samples were analysed with ADVIA Centaur® CP Immunoassay, Abbott Architect i1000® immunoassay and AB Sciex 5500 liquid chromatography-tandem mass spectrometry (LC-MS/MS) systems. Per cent bias was determined for each system to report the average tendency of the values to be larger or smaller than the LC-MS/MS value. Linear regression of total follicular volume and oestradiol was computed. Results The ADVIA Centaur® CP assay had a positive bias of 20% compared with LC-MS/MS, while the Architect i1000® had a non-significant, negative bias of 0.3%. With regression fit, a clear, positive relationship was seen between follicular volume and oestradiol. The Architect i1000® assay had a greater correlation (R2 = 0.46) compared with Centaur® CP (R2 = 0.36), when oestradiol values were >1000 pg/mL (3670 pmol/L). Conclusions The Abbott Architect i1000® oestradiol assay exhibits greater agreement with LC-MS/MS and exhibited better correlation to follicular volume when oestradiol values are >1000 pg/mL (3670 pmol/L), prompting a change in the clinic's oestradiol platform. Attention to assay quality assurance via LC-MS/MS can improve the oestradiol accuracy and permit more informed clinical decisions for improved patient outcomes.

Entities:  

Keywords:  Analytes; immunoassay; laboratory methods; mass spectrometry; steroid hormones

Mesh:

Substances:

Year:  2017        PMID: 28166666     DOI: 10.1177/0004563217691788

Source DB:  PubMed          Journal:  Ann Clin Biochem        ISSN: 0004-5632            Impact factor:   2.057


  3 in total

1.  Simultaneous measurement of total estradiol and testosterone in human serum by isotope dilution liquid chromatography tandem mass spectrometry.

Authors:  Hui Zhou; Yuesong Wang; Matthew Gatcombe; Jacob Farris; Julianne C Botelho; Samuel P Caudill; Hubert W Vesper
Journal:  Anal Bioanal Chem       Date:  2017-08-11       Impact factor: 4.142

2.  A New LC-MS/MS Method for Simultaneous and Quantitative Detection of Bisphenol-A and Steroids in Target Tissues: A Power Tool to Characterize the Interference of Bisphenol-A Exposure on Steroid Levels.

Authors:  Sonia Errico; Teresa Chioccarelli; Martina Moggio; Nadia Diano; Gilda Cobellis
Journal:  Molecules       Date:  2019-12-21       Impact factor: 4.411

3.  TNF-α Regulated Endometrial Stroma Secretome Promotes Trophoblast Invasion.

Authors:  Yuan You; Patrick Stelzl; Dana N Joseph; Paulomi B Aldo; Anthony J Maxwell; Nava Dekel; Aihua Liao; Shannon Whirledge; Gil Mor
Journal:  Front Immunol       Date:  2021-11-01       Impact factor: 7.561

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.