Literature DB >> 28166173

Is This Autograft Worth It?: The Blood Loss and Transfusion Rates Associated With Reamer Irrigator Aspirator Bone Graft Harvest.

Lucas S Marchand1, David L Rothberg, Erik N Kubiak, Thomas F Higgins.   

Abstract

OBJECTIVES: To investigate the blood loss and transfusion rate associated with the use of reamer irrigator aspirator (RIA).
DESIGN: Retrospective review.
SETTING: Academic Level-I trauma hospital. PATIENTS: One hundred eight patients requiring bone graft harvest for surgical reconstruction of nonunion or failed arthrodesis. INTERVENTION: Bone graft harvest preformed via RIA or iliac crest bone graft (ICBG). MAIN OUTCOME MEASURE: Blood loss as measured by a change in preoperative and postoperative hematocrit (Hct). In addition, postoperative transfusion reported intraoperative blood loss, volume of graft harvested, and major complications.
RESULTS: The average Hct drop was found to be 13.7 (4.1-27.4) in the RIA cohort of 61 patients and 7.36 (1.2-14.5) in the ICBG cohort of 47 patients (P = 0.013). Operative reports documented an average estimated blood loss of 674 mL (100-2000 mL) in the RIA cohort compared with 255 mL (50-1000 mL) in the ICBG cohort (P < 0.001). Twenty-seven patients (44%) required blood transfusion after RIA, whereas 10 patients (21%) required blood transfusion after ICBG (odds ratio 5.32, 95% confidence interval 2.2-6.3, P < 0.001). RIA procedures collected an average 53 mL (20-100 mL) of bone graft compared with 27 mL (15-50 mL) with ICBG. There was no significant difference between groups regarding age, sex, medical comorbidities, or postoperative major complications.
CONCLUSIONS: This series demonstrated that 44% of patients undergoing RIA bone graft harvest required transfusion, with a mean Hct drop of 13.7 across all subjects, which is significantly greater than that associated with ICBG. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2017        PMID: 28166173     DOI: 10.1097/BOT.0000000000000811

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  6 in total

1.  The Reamer-Irrigator-Aspirator (RIA) System for the treatment of aseptic femoral nonunions: Report of two cases and literature review.

Authors:  Marco Landrino; Riccardo Luigi Alberio; Alice Clemente; Federico Alberto Grassi
Journal:  Orthop Rev (Pavia)       Date:  2022-10-04

Review 2.  Complications associated using the reamer-irrigator -aspirator (RIA) system: a systematic review and meta-analysis.

Authors:  Markus Laubach; Lucas P Weimer; Felix M Bläsius; Frank Hildebrand; Philipp Kobbe; Dietmar W Hutmacher
Journal:  Arch Orthop Trauma Surg       Date:  2022-09-17       Impact factor: 2.928

3.  Quantitative bone single-photon emission computed tomography imaging for uninfected nonunion: comparison of hypertrophic nonunion and non-hypertrophic nonunion.

Authors:  Keisuke Oe; Feibi Zeng; Tomoaki Fukui; Munenobu Nogami; Takamichi Murakami; Tomoyuki Matsumoto; Ryosuke Kuroda; Takahiro Niikura
Journal:  J Orthop Surg Res       Date:  2021-02-10       Impact factor: 2.359

4.  Safety and efficacy of a novel retrograde route for femoral bone graft harvesting by Reamer-Irrigator-Aspirator: a pilot study on 24 patients.

Authors:  Fernando Bidolegui; Sebastián Pereira; Cristina Irigoyen; Robinson Esteves Pires
Journal:  Patient Saf Surg       Date:  2022-01-07

5.  Outcomes and complications of the reamer irrigator aspirator versus traditional iliac crest bone graft harvesting: a systematic review and meta-analysis.

Authors:  Francesco Oliva; Filippo Migliorini; Francesco Cuozzo; Ernesto Torsiello; Frank Hildebrand; Nicola Maffulli
Journal:  J Orthop Traumatol       Date:  2021-12-01

6.  Fusion Revision Surgery With Reamer-Irrigator-Aspirator to Harvest Autograft After Spinal Pseudarthrosis.

Authors:  Ahmed H Elhessy; Hady H Eltayeby; Stephen C Kane; Ira M Garonzik; James E Conway; Janet D Conway
Journal:  Cureus       Date:  2022-07-31
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.