Literature DB >> 28164489

Multiplex PCR for the Detection of 10 Viruses Causing Encephalitis/Encephalopathy and its Application to Clinical Samples Collected from Japanese Children with Suspected Viral.

Ngan T K Pham, Hiroshi Ushijima, Aksara Thongprachum, Quang D Trinh, Pattara Khamrin, Chikako Arakawa, Wakako Ishii, Shoko Okitsu, Shihoko Komine-Aizawa, Satoshi Hayakawa.   

Abstract

BACKGROUND: Acute encephalitis is a serious neurological condition having a high mortality rate and affecting both children and adults. This study aimed to develop a multiplex PCR method for the simultaneous screening of clinical samples for the presence of the 10 viruses presently considered as the major viral causes of acute encephalitis/ encephalopathy in Asia.
METHODS: Using previously published primers that have been widely used to screen for herpes virus-6, influenza A virus, human parechovirus, herpes simplex viruses 1 and 2, Japanese encephalitis virus, group A rotavirus, enterovirus, adenovirus, and dengue virus in clinical samples, a single-tube multiplex PCR assay was developed and was tested for its sensitivity and specificity. The method was then applied to screen 57 clinical samples, consisting of 13 fecal samples, 5 throat swabs, 3 post-nasal swabs, 18 serum samples, and 18 cerebrospinal fluid (CSF) samples, collected from 18 hospitalized Japanese children with suspected viral encephalitis/encephalopathy for the target viruses, and the results were compared with those of a monoplex PCR method.
RESULTS: Positive viral controls of the 10 viruses were correctly typed using this multiplex PCR method. The multiplex PCR method showed high specificity with no unspecific amplification to non-target viruses. The results of applying this PCR method for screening clinical samples showed that 6 fecal samples, 2 serum samples, and 1 CSF sample collected from 7 patients were positive for a virus, specifically group A rotavirus (4 patients, 22.2%), enterovirus (2 patients, 11.1%), or adenovirus (1 patient, 5.6%). In comparison with monoplex PCR, for group A rotavirus, enterovirus, and adenovirus, the sensitivity of this multiplex PCR method decreased for serum, cerebrospinal fluid, and throat swab samples.
CONCLUSIONS: This newly developed multiplex PCR method is a simple, rapid diagnostic tool and can be used to screen clinical samples for viruses causing acute encephalitis/encephalopathy in children in Asian countries.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28164489     DOI: 10.7754/Clin.Lab.2016.160630

Source DB:  PubMed          Journal:  Clin Lab        ISSN: 1433-6510            Impact factor:   1.138


  1 in total

1.  A rapid and accurate method for the detection of four aminoglycoside modifying enzyme drug resistance gene in clinical strains of Escherichia coli by a multiplex polymerase chain reaction.

Authors:  Yaoqiang Shi; Chao Li; Guangying Yang; Xueshan Xia; Xiaoqin Mao; Yue Fang; A-Mei Zhang; Yuzhu Song
Journal:  PeerJ       Date:  2020-04-10       Impact factor: 2.984

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.