Literature DB >> 28161895

Comparative study of dental enamel loss after debonding braces by analytical scanning electron microscopy (SEM).

Jacqueline Adelina Rodríguez-Chávez1, Jesús Arenas-Alatorre2, Irma Araceli Belio-Reyes3.   

Abstract

Clinical procedures when shear forces are applied to brackets suggest adhesion forces between 2.8 and 10.0 MPa as appropriate. In this study dental enamel was evaluated by scanning electron microscopy (SEM) before and after removing the brackets. Thirty bicuspids (previous prophylaxis) with metallic brackets (Roth Inovation 0.022 GAC), Transbond Plus SEP 3M Unitek adhesive and Transbond XT 3M resin were used. The samples were preserved to 37°C during 24 hr and submited to tangential forces with the Instron Universal machine 1.0 mm/min speed load strength resistance debonding. Also the Adhesive Remanent Index (ARI) test was made, evaluating the bracket base and the bicuspid surface. All the bracket SEM images were processed with AutoCAD to determine the enamel detached area. The average value was 6.86 MPa (SD ± 3.2 MPa). ARI value 1= 63.3%, value 2= 20%, value 3= 13.3% and 33% presented value 0. All those samples with dental enamel loss, presented different situations as fractures, ledges, horizontal, and vertical loss in some cases, and some scratch lines. There is no association between the debonding resistance and enamel presence. Less than half of the remanent adhesive on the dental enamel was present in most of the samples when the ARI test was applied. When the resin area increases, the debonding resistance also increases, and when the enamel loss increases, the resin free metallic area of the bracket base decreases in the debonding.
© 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  SEM; debonding forces; enamel; enamel loss; self-etch adhesive; shear bond strength

Mesh:

Substances:

Year:  2017        PMID: 28161895     DOI: 10.1002/jemt.22849

Source DB:  PubMed          Journal:  Microsc Res Tech        ISSN: 1059-910X            Impact factor:   2.769


  2 in total

1.  Evaluation of Enamel Topography after Debonding Orthodontic Ceramic Brackets by Different Er,Cr:YSGG and Er:YAG Lasers Settings.

Authors:  Marwan Hoteit; Samir Nammour; Toni Zeinoun
Journal:  Dent J (Basel)       Date:  2020-01-09

2.  Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: An In Vitro Study.

Authors:  Álvaro Zubizarreta-Macho; Martina Triduo; Jorge Alonso Pérez-Barquero; Clara Guinot Barona; Alberto Albaladejo Martínez
Journal:  J Clin Med       Date:  2020-04-12       Impact factor: 4.241

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.