Literature DB >> 28160298

Fluoroless Catheter Ablation of Cardiac Arrhythmias: A 5-Year Experience.

Mansour Razminia1, Michael Cameron Willoughby1, Hany Demo1, Hesam Keshmiri1, Theodore Wang1, Oliver J D'Silva1, Terry A Zheutlin1, Hakeem Jibawi1, Paul Okhumale1, Richard F Kehoe1.   

Abstract

BACKGROUND: Catheter ablations have been traditionally performed with the use of fluoroscopic guidance, which exposes the patient and staff to the inherent risks of radiation. We have developed techniques to eliminate the use of fluoroscopy during cardiac ablations and have been performing completely fluoroless catheter ablations on our patients for over 5 years.
METHODS: We present a retrospective analysis of the safety, efficacy, and feasibility data from 500 consecutive patients who underwent nonfluoroscopic catheter ablation, targeting a total of 639 arrhythmias, including atrioventricular reciprocating tachycardia (AVRT), atrioventricular nodal reentrant tachycardia (AVNRT), atrial tachycardia (AT), atrial fibrillation (AF), premature ventricular contractions (PVCs), and ventricular tachycardia (VT). We perform fluoroless ablations using intracardiac electrograms, electroanatomic mapping, and for most cases intracardiac echocardiography. Our experience includes exclusively endocardial cardiac ablations.
RESULTS: The mean follow-up was 20.5 months. Recurrence rate for AVRT was 6.5%, for AVNRT 2.5%, for macro-reentrant AT 6.4%, for focal AT 5.4%, for AF 22.6%, for PVC 6.7%, and for VT 21.4%. Major complications occurred in five patients (1.0%); minor complications occurred in three patients (0.6%). No deaths occurred. Fluoroscopy was used in one instance, for 0.3 minutes, to confirm venous access.
CONCLUSIONS: Completely fluoroless catheter ablations may be routinely performed for all endocardial ablations without compromising safety, efficacy, or procedural duration.
© 2017 The Authors. Pacing and Clinical Electrophysiology published by Wiley Periodicals, Inc.

Entities:  

Keywords:  ablation; arrhythmia; fluoroless

Mesh:

Year:  2017        PMID: 28160298     DOI: 10.1111/pace.13038

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  27 in total

1.  [Radiation reduction in interventional electrophysiology : Results from operators with different levels of experience].

Authors:  Miriam Schnur; Severin Wannagat; Lena Loehr; Sebastian Lask; Andreas Mügge; Alexander Wutzler
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2018-12

2.  Fluoroscopy-free AF ablation using transesophageal echocardiography and electroanatomical mapping technology.

Authors:  Benjamin O'Brien; Damian C Balmforth; Ross J Hunter; Richard J Schilling
Journal:  J Interv Card Electrophysiol       Date:  2017-11-14       Impact factor: 1.900

3.  Zero-Fluoroscopy Ablation at the Texas Heart Institute.

Authors:  David Burkland
Journal:  Tex Heart Inst J       Date:  2020-02-01

4.  Implementation of a near-zero fluoroscopy approach in interventional electrophysiology: impact of operator experience.

Authors:  Severin Wannagat; Lena Loehr; Sebastian Lask; Katharina Völk; Tamer Karaköse; Cemil Özcelik; Andreas Mügge; Alexander Wutzler
Journal:  J Interv Card Electrophysiol       Date:  2018-02-19       Impact factor: 1.900

5.  Comparison of cryoballoon and radiofrequency ablation for persistent atrial fibrillation: a systematic review and meta-analysis.

Authors:  Jitae A Kim; Mihail G Chelu
Journal:  J Interv Card Electrophysiol       Date:  2022-09-12       Impact factor: 1.759

6.  Combined use of electro-anatomic mapping system and intracardiac echocardiography to achieve zero-fluoroscopy catheter ablation for treatment of paroxysmal atrial fibrillation: a single centre experience.

Authors:  Matevž Jan; David Žižek; Dimitrij Kuhelj; Nikola Lakič; Tine Prolič Kalinšek; Jernej Štublar; Luka Klemen; Andrej Pernat; Bor Antolič
Journal:  Int J Cardiovasc Imaging       Date:  2019-11-11       Impact factor: 2.357

7.  Zero Fluoroscopy During Ablation of Right-Sided Supraventricular Tachycardia Substrates in a Pediatric Population - Initial Experience in Taiwan.

Authors:  Wei-Chieh Tseng; Mei-Hwan Wu; Chun-Wei Lu; Kun-Lang Wu; Jou-Kou Wang; Ming-Tai Lin; Chun-An Chen; Shuenn-Nan Chiu
Journal:  Acta Cardiol Sin       Date:  2019-09       Impact factor: 2.672

8.  Fluoroless Catheter Ablation of Atrial Fibrillation: Integration of Intracardiac Echocardiography and Cartosound Module.

Authors:  Enes Elvin Gul; Zahra Azizi; Pouria Alipour; Sohaib Haseeb; Rebecca Malcolm; Maria Terricabras; Paula Sanchez Somonte; Bernice Tsang; Yaariv Khaykin; Zaev Wulffhart; Atul Verma; Alfredo Pantano
Journal:  J Atr Fibrillation       Date:  2021-08-31

9.  Fluoroless left atrial access for radiofrequency and cryoballoon ablations using a novel radiofrequency transseptal wire.

Authors:  Hany Demo; Carla Aranda; Mansour Razminia
Journal:  J Interv Card Electrophysiol       Date:  2022-02-22       Impact factor: 1.759

10.  Atrial Fibrillation Ablation Without Fluoroscopy: Because We Can.

Authors:  Rahul N Doshi
Journal:  J Innov Card Rhythm Manag       Date:  2018-11-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.