Literature DB >> 28160204

The effect of different cleaning methods on the surface and temperature of failed titanium implants: an in vitro study.

Sema S Hakki1,2, Gulsah Tatar3, Niyazi Dundar4, Burak Demiralp5.   

Abstract

The aims of this in vitro study are to compare the efficacy of different cleaning methods in removing debris of failed implants and to detect thermal changes of the implants treated by various scaling instruments. Twenty-seven failed implants and two unused implants as control were included to this study-group 1: plastic curette (P), group 2: titanium curette (T), group 3: carbon curette (C), group 4: titanium brush (TB), group 5: Er:YAG laser (laser 1 (L1) 100 mJ/pulse at 10 Hz), group 6: Er:YAG laser (laser 2 (L2) 150 mJ/pulse at 10 Hz), group 7: Er:YAG laser (laser 3 (L3) 200 mJ/pulse at 10 Hz), group 8: ultrasonic scaler appropriate for titanium (US), group 9: air abrasive method (AA) + citric acid, and group 10: implantoplasty (I). The changes on the treated/untreated titanium surfaces and remnant debris were observed by scanning electron microscopy (SEM). Temperature of the implants before and after treatment was detected using a thermocouple. The use of air abrasive and citric acid combination and Er:YAG laser groups was found as the best methods for the decontamination of titanium surfaces of failed implant. When the hand instruments were compared, titanium curette was found better than both the plastic and the carbon curettes which leave plastics and carbon remnants on the titanium surface. The temperature was higher after hand instrumentation when compared to other experimental groups (p < 0.05). Within the limitations of the present in vitro model, it can be concluded that the best method for decontamination of the implant surface is the use of air abrasives and Er:YAG laser.

Entities:  

Keywords:  Air abrasive; Er:YAG laser; Hand instruments; Implant surface; Temperature; Ultrasonic scaler

Mesh:

Substances:

Year:  2017        PMID: 28160204     DOI: 10.1007/s10103-017-2149-2

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  5 in total

1.  A comparison of human dental pulp stem cell activity cultured on sandblasted titanium discs decontaminated with Er:YAG laser and air-powder abrasion: an in vitro study.

Authors:  Mahdi Kadkhodazadeh; Reza Amid; Maedeh Gilvari Sarshari; Massoud Mojahedi; Ardavan Parhizkar
Journal:  Lasers Med Sci       Date:  2022-07-30       Impact factor: 2.555

2.  Effect of a Er, Cr:YSGG laser and a Er:YAG laser treatment on oral biofilm-contaminated titanium.

Authors:  So-Hyun Park; Ok-Joon Kim; Hyun-Ju Chung; Ok-Su Kim
Journal:  J Appl Oral Sci       Date:  2020-11-30       Impact factor: 2.698

3.  The Prevention of Implant Surface Alterations in the Treatment of Peri-Implantitis: Comparison of Three Different Mechanical and Physical Treatments.

Authors:  Marco Lollobrigida; Lorenzo Fortunato; Giorgio Serafini; Giulia Mazzucchi; Giuseppina Bozzuto; Agnese Molinari; Emanuele Serra; Francesca Menchini; Iole Vozza; Alberto De Biase
Journal:  Int J Environ Res Public Health       Date:  2020-04-11       Impact factor: 3.390

4.  Simulated damage of two implant debridement methods: Nonsurgical approach with Teflon and stainless steel hand scalers.

Authors:  João Paulo Mendes Tribst; Amanda Maria de Oliveira Dal Piva; Dimas Renno de Lima; Alexandre Luiz Souto Borges; Marco Antonio Bottino
Journal:  J Indian Soc Periodontol       Date:  2018 Jul-Aug

5.  Dental implant surface temperatures following double wavelength (2780/940 nm) laser irradiation in vitro.

Authors:  Peter Fahlstedt; Dagmar F Bunaes; Stein Atle Lie; Knut N Leknes
Journal:  Clin Exp Dent Res       Date:  2020-12-04
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.