Literature DB >> 28159668

Performance analysis of two immunochromatographic assays for the diagnosis of rotavirus infection.

S De Grazia1, F Bonura2, A Pepe2, S Li Muli2, V Cappa2, A Collura3, D M Terranova3, N Urone2, F Di Bernardo3, D Matranga2, G M Giammanco2.   

Abstract

Group A rotaviruses (RVAs) are the primary cause of acute gastroenteritis (AGE) in young children worldwide. Several commercial tests including latex agglutination, enzyme-linked assays (ELISA) and immunochromatographic tests (ICT) have been developed for the diagnosis of RVA infection. In the present study, the performance of two commercially available one-step chromatographic immunoassays, CerTest Rotavirus+Adenovirus (Biotec S.L, Zaragoza, Spain) and Vikia Rota-Adeno (bioMerieux SA, Lyon, France) were retrospectively evaluated using Real-time PCR as reference test. Re-testing by Real-time PCR of 2096 stool samples of children hospitalized with AGE previously screened by ICTs (1467 by CerTest and 629 by Vikia) allowed to calculate higher sensitivity for Vikia (94% vs 85% of CerTest) and higher specificity for CerTest (93% vs 89% of Vikia). Accordingly, higher Positive Predictive Values (87% vs 78%) and Positive Likelihood Ratios (12.32 vs 8.8) were found for CerTest and lower Negative Predictive Values (91% vs 97%) and Negative Likelihood Ratios (0.16 vs 0.06) for Vikia. However, both CerTest and Vikia showed a substantial agreement (κ=0.79) with the Real-time PCR. A correlation between false negative results by ICTs and high Cycle Threshold values of Real-time PCR, indicative of low viral load, was observed. False positive results by the two ICT assays were not related to Norovirus, Adenovirus or Astrovirus infections, therefore the risk of cross-reactions was excluded. Both CerTest and VIKIA were able to detect the wide range of RVA genotypes circulating over the study period (including G1P[8], G2P[4], G3, G4, G9 and G12P[8]). The results of the present study showed a satisfactory efficacy of the two diagnostic tests analyzed.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Immunochromatography; Rotavirus; Sentitivity; Specificity

Mesh:

Year:  2017        PMID: 28159668     DOI: 10.1016/j.jviromet.2017.01.025

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  2 in total

1.  Diagnostic Accuracy of Four Commercial Triplex Immunochromatographic Tests for Rapid Detection of Rotavirus, Adenovirus, and Norovirus in Human Stool Samples.

Authors:  Jérôme Kaplon; Lucie Théry; Maxime Bidalot; Nadège Grangier; Jean Frappier; Ludwig Serge Aho Glélé; Alexis de Rougemont; Katia Ambert-Balay
Journal:  J Clin Microbiol       Date:  2020-12-17       Impact factor: 11.677

2.  Performance evaluation of Automated Fluorescent Immunoassay System ROTA and NORO for detection of rotavirus and norovirus: A comparative study of assay performance with RIDASCREEN® Rotavirus and Norovirus.

Authors:  Changhee Ha; In Young Yoo; Sun Ae Yun; Yoo Na Chung; Hee Jae Huh; Nam Yong Lee
Journal:  J Clin Lab Anal       Date:  2020-09-23       Impact factor: 2.352

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.