Turbid elution pools and high column back pressure are common during elution of monoclonal antibodies (mAbs) by acidic pH in Protein A chromatography. This phenomenon has been historically attributed to acid-induced precipitation of incorrectly folded or pH-sensitive mAbs and host cell proteins (HCPs). In this work, we propose a new mechanism that may account for some observations of elution turbidity in Protein A chromatography. We report several examples of turbidity and high column back pressure occurring transiently under a short course of neutral conditions during Protein A elution. A systematic study of three mAbs displaying this behavior revealed phase separation characterized by liquid drops under certain conditions including neutral pH, low ionic strength, and high protein concentration. These liquid droplets caused solution turbidity and exhibited extremely high viscosity, resulting in high column back pressure. We found out that the droplets were formed through liquid-liquid phase separation (LLPS) as a result of protein self-association. We also found multiple factors, including pH, temperature, ionic strength, and protein concentration can affect LLPS behaviors. Careful selection of process parameters during protein A elution, including temperature, flow rate, buffer, and salt can inhibit formation of a dense liquid phase, reducing both turbidity (by 90%) and column back pressure (below 20 pounds per square inch). These findings provide both mechanistic insight and practical mitigation strategies for Protein A chromatography induced LLPS.
Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

Keywords:  Column back pressure; Dense phase; Liquid-liquid phase separation (LLPS); Monoclonal antibody (mAb); Protein A chromatography; Reversible self-association; Transient turbidity; Viscosity

Mesh:

Substances:

Year:  2017        PMID: 28159365     DOI: 10.1016/j.chroma.2017.01.067

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  Process optimization and protein engineering mitigated manufacturing challenges of a monoclonal antibody with liquid-liquid phase separation issue by disrupting inter-molecule electrostatic interactions.

Authors:  Qun Du; Melissa Damschroder; Timothy M Pabst; Alan K Hunter; William K Wang; Haibin Luo
Journal:  MAbs       Date:  2019-04-14       Impact factor: 5.857

2.  Comprehensive Assessment of Protein and Excipient Stability in Biopharmaceutical Formulations Using 1H NMR Spectroscopy.

Authors:  Jack E Bramham; Adrian Podmore; Stephanie A Davies; Alexander P Golovanov
Journal:  ACS Pharmacol Transl Sci       Date:  2020-12-16
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.