Literature DB >> 28157991

High-sensitivity and wide-range optical sensor based on three cascaded ring resonators.

Yong Liu, Yang Li, Mingyu Li, Jian-Jun He.   

Abstract

We demonstrate a three cascaded micro-ring resonators based refractive index optical sensor with a high sensitivity of 5866 nm/RIU, the measurement range of which is significantly improved 24.7 times comparing with the traditional two cascaded micro-ring resonators.

Year:  2017        PMID: 28157991     DOI: 10.1364/OE.25.000972

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  3 in total

1.  Design Rule of Mach-Zehnder Interferometer Sensors for Ultra-High Sensitivity.

Authors:  Yiwei Xie; Ming Zhang; Daoxin Dai
Journal:  Sensors (Basel)       Date:  2020-05-05       Impact factor: 3.576

Review 2.  Silicon Photonic Biosensors Using Label-Free Detection.

Authors:  Enxiao Luan; Hossam Shoman; Daniel M Ratner; Karen C Cheung; Lukas Chrostowski
Journal:  Sensors (Basel)       Date:  2018-10-18       Impact factor: 3.576

Review 3.  Optical Biosensors Based on Silicon-On-Insulator Ring Resonators: A Review.

Authors:  Patrick Steglich; Marcel Hülsemann; Birgit Dietzel; Andreas Mai
Journal:  Molecules       Date:  2019-01-31       Impact factor: 4.411

  3 in total