Literature DB >> 28157950

Liquid crystal spherical microlens array with high fill factor and optical power.

José Francisco Algorri, Virginia Urruchi, Noureddine Bennis, Przemek Morawiak, José Manuel Sánchez-Pena, José Manuel Otón.   

Abstract

A novel liquid crystal spherical microlens array with high optical power and almost 100% of fill-factor is proposed and experimentally demonstrated. The combination of a specific structure and electrical waveforms applied to the electrodes generates an array of spherical microlenses with square aperture. The manufacturing process is simple (patterned electrodes) and the microlenses are reconfigurable by low voltage signals (the electrodes are in contact with the LC layer). This device could be a key for the next generation of autostereoscopic devices based on Integral Imaging technique.

Year:  2017        PMID: 28157950     DOI: 10.1364/OE.25.000605

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  5 in total

1.  Positive-negative tunable liquid crystal lenses based on a microstructured transmission line.

Authors:  J F Algorri; P Morawiak; N Bennis; D C Zografopoulos; V Urruchi; L Rodríguez-Cobo; L R Jaroszewicz; J M Sánchez-Pena; J M López-Higuera
Journal:  Sci Rep       Date:  2020-06-23       Impact factor: 4.379

2.  Depth-of-Field-Extended Plenoptic Camera Based on Tunable Multi-Focus Liquid-Crystal Microlens Array.

Authors:  Mingce Chen; Wenda He; Dong Wei; Chai Hu; Jiashuo Shi; Xinyu Zhang; Haiwei Wang; Changsheng Xie
Journal:  Sensors (Basel)       Date:  2020-07-25       Impact factor: 3.576

Review 3.  Infiltrated Photonic Crystal Fibers for Sensing Applications.

Authors:  José Francisco Algorri; Dimitrios C Zografopoulos; Alberto Tapetado; David Poudereux; José Manuel Sánchez-Pena
Journal:  Sensors (Basel)       Date:  2018-12-04       Impact factor: 3.576

4.  Electrically Controlled Liquid Crystal Microlens Array Based on Single-Crystal Graphene Coupling Alignment for Plenoptic Imaging.

Authors:  Mingce Chen; Qi Shao; Wenda He; Dong Wei; Chai Hu; Jiashuo Shi; Kewei Liu; Haiwei Wang; Changsheng Xie; Xinyu Zhang
Journal:  Micromachines (Basel)       Date:  2020-11-26       Impact factor: 2.891

5.  All-In-Focus Polarimetric Imaging Based on an Integrated Plenoptic Camera with a Key Electrically Tunable LC Device.

Authors:  Mingce Chen; Zhexun Li; Mao Ye; Taige Liu; Chai Hu; Jiashuo Shi; Kewei Liu; Zhe Wang; Xinyu Zhang
Journal:  Micromachines (Basel)       Date:  2022-01-26       Impact factor: 2.891

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.