Literature DB >> 28156122

Implant Insertion Torque: Its Role in Achieving Primary Stability of Restorable Dental Implants.

Gary Greenstein1, John Cavallaro2.   

Abstract

A literature review was conducted to determine the role of insertion torque in attaining primary stability of dental implants. The review is comprised of articles that discussed the amount of torque needed to achieve primary implant stability in healed ridges and fresh extraction sockets prior to immediate implant loading. Studies were appraised that addressed the effects of minimum and maximum forces that can be used to successfully place implants. The minimum torque that can be employed to attain primary stability is undefined. Forces ≥30 Ncm are routinely used to place implants into healed ridges and fresh extraction sockets prior to immediate loading of implants. Increased insertion torque (≥50 Ncm) reduces micromotion and does not appear to damage bone. In general, the healing process after implant insertion provides a degree of biologic stability that is similar whether implants are placed with high or low initial insertion torque. Primary stability is desirable when placing implants, but the absence of micromotion is what facilitates predictable implant osseointegration. Increased insertion torque helps achieve primary stability by reducing implant micromotion. Furthermore, tactile information provided by the first surgical twist drill can aid in selecting the initial insertion torque to achieve predictable stability of inserted dental implants.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28156122

Source DB:  PubMed          Journal:  Compend Contin Educ Dent        ISSN: 1548-8578


  11 in total

1.  Correlation between the thickness of the crestal and buccolingual cortical bone at varying depths and implant stability quotients.

Authors:  Kanthanat Chatvaratthana; Sita Thaworanunta; Dutmanee Seriwatanachai; Natthamet Wongsirichat
Journal:  PLoS One       Date:  2017-12-27       Impact factor: 3.240

2.  Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles.

Authors:  Fernanda Faot; Amália Machado Bielemann; Alessandra Julie Schuster; Raissa Micaella Marcello-Machado; Altair Antoninha Del Bel Cury; Gustavo G Nascimento; Otacílio Luiz Chagas-Junior
Journal:  Biomed Res Int       Date:  2019-06-02       Impact factor: 3.411

Review 3.  Stability of Dental Implants and Thickness of Cortical Bone: Clinical Research and Future Perspectives. A Systematic Review.

Authors:  Danilo Alessio Di Stefano; Paolo Arosio; Paolo Capparè; Silvia Barbon; Enrico Felice Gherlone
Journal:  Materials (Basel)       Date:  2021-11-25       Impact factor: 3.623

4.  Correlation between Primary, Secondary Stability, Bone Density, Percentage of Vital Bone Formation and Implant Size.

Authors:  Vasilena Ivanova; Ivan Chenchev; Stefan Zlatev; Eitan Mijiritsky
Journal:  Int J Environ Res Public Health       Date:  2021-06-30       Impact factor: 3.390

5.  Does Oral Implant Design Affect Marginal Bone Loss? Results of a Parallel-Group Randomized Controlled Equivalence Trial.

Authors:  Benedikt C Spies; Maria Bateli; Ghada Ben Rahal; Marin Christmann; Kirstin Vach; Ralf-Joachim Kohal
Journal:  Biomed Res Int       Date:  2018-01-31       Impact factor: 3.411

6.  The effect of implant placement torque on crestal bone remodeling after 1 year of loading.

Authors:  Salwa Aldahlawi; Angela Demeter; Tassos Irinakis
Journal:  Clin Cosmet Investig Dent       Date:  2018-10-09

7.  A Retrospective Study on Insertion Torque and Implant Stability Quotient (ISQ) as Stability Parameters for Immediate Loading of Implants in Fresh Extraction Sockets.

Authors:  Giuseppe Bavetta; Giorgio Bavetta; Valentina Randazzo; Alessio Cavataio; Carlo Paderni; Vincenzo Grassia; Gianna Dipalma; Ciro Gargiulo Isacco; Antonio Scarano; Danila De Vito; Stefania Cantore; Andrea Ballini; Francesco Inchingolo
Journal:  Biomed Res Int       Date:  2019-11-03       Impact factor: 3.411

8.  Effect of bone quality and quantity on the primary stability of dental implants in a simulated bicortical placement.

Authors:  Stefan Rues; Marc Schmitter; Stefanie Kappel; Robert Sonntag; Jan Philippe Kretzer; Jan Nadorf
Journal:  Clin Oral Investig       Date:  2020-07-10       Impact factor: 3.573

9.  Molar Septum Expansion with Osseodensification for Immediate Implant Placement, Retrospective Multicenter Study with Up-to-5-Year Follow-Up, Introducing a New Molar Socket Classification.

Authors:  Samvel Bleyan; João Gaspar; Salah Huwais; Charles Schwimer; Ziv Mazor; José João Mendes; Rodrigo Neiva
Journal:  J Funct Biomater       Date:  2021-11-25

10.  Peri-implant bone preservation of a novel, self-cutting, and fully tapered implant in the healed crestal ridge of minipigs: submerged vs. transgingival healing.

Authors:  Helena Francisco; Gary Finelle; Fabien Bornert; Rebecca Sandgren; Valentin Herber; Nils Warfving; Benjamin E Pippenger
Journal:  Clin Oral Investig       Date:  2021-05-05       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.