Literature DB >> 28154126

Diagnostic Quality of 3D T2-SPACE Compared with T2-FSE in the Evaluation of Cervical Spine MRI Anatomy.

F H Chokshi1,2, G Sadigh3, W Carpenter4, J W Allen3,5.   

Abstract

BACKGROUND AND
PURPOSE: Spinal anatomy has been variably investigated using 3D MRI. We aimed to compare the diagnostic quality of T2 sampling perfection with application-optimized contrasts by using flip angle evolution (SPACE) with T2-FSE sequences for visualization of cervical spine anatomy. We predicted that T2-SPACE will be equivalent or superior to T2-FSE for visibility of anatomic structures.
MATERIALS AND METHODS: Adult patients undergoing cervical spine MR imaging with both T2-SPACE and T2-FSE sequences for radiculopathy or myelopathy between September 2014 and February 2015 were included. Two blinded subspecialty-trained radiologists independently assessed the visibility of 12 anatomic structures by using a 5-point scale and assessed CSF pulsation artifact by using a 4-point scale. Sagittal images and 6 axial levels from C2-T1 on T2-FSE were reviewed; 2 weeks later and after randomization, T2-SPACE was evaluated. Diagnostic quality for each structure and CSF pulsation artifact visibility on both sequences were compared by using a paired t test. Interobserver agreement was calculated (κ).
RESULTS: Forty-five patients were included (mean age, 57 years; 40% male). The average visibility scores for intervertebral disc signal, neural foramina, ligamentum flavum, ventral rootlets, and dorsal rootlets were higher for T2-SPACE compared with T2-FSE for both reviewers (P < .001). Average scores for remaining structures were either not statistically different or the superiority of one sequence was discordant between reviewers. T2-SPACE showed less degree of CSF flow artifact (P < .001). Interobserver variability ranged between -0.02-0.20 for T2-SPACE and -0.02-0.30 for T2-FSE (slight to fair agreement).
CONCLUSIONS: T2-SPACE may be equivalent or superior to T2-FSE for the evaluation of cervical spine anatomic structures, and T2-SPACE shows a lower degree of CSF pulsation artifact.
© 2017 by American Journal of Neuroradiology.

Entities:  

Mesh:

Year:  2017        PMID: 28154126     DOI: 10.3174/ajnr.A5080

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  8 in total

1.  Reply.

Authors:  F H Chokshi; G Sadigh; W Carpenter; J W Allen
Journal:  AJNR Am J Neuroradiol       Date:  2017-04-27       Impact factor: 3.825

2.  3D T2-SPACE versus T2-FSE or T2 Gradient Recalled-Echo: Which Is the Best Sequence?

Authors:  M I Vargas; J L Dietemann
Journal:  AJNR Am J Neuroradiol       Date:  2017-04-27       Impact factor: 3.825

3.  Quality comparison between three-dimensional T2-weighted SPACE and two-dimensional T2-weighted turbo spin echo magnetic resonance images for the brachytherapy planning evaluation of prostate and periprostatic anatomy.

Authors:  Tharakeswara K Bathala; Aradhana M Venkatesan; Jingfei Ma; Priyadarshini Bhosale; Wei Wei; Rajat J Kudchadker; Jihong Wang; Mitchell S Anscher; Chad Tang; Teresa L Bruno; Steven J Frank; Janio Szklaruk
Journal:  Brachytherapy       Date:  2020-05-10       Impact factor: 2.362

Review 4.  Tentorium Cerebelli: Muscles, Ligaments, and Dura Mater, Part 1.

Authors:  Bruno Bordoni; Marta Simonelli; Maria Marcella Lagana
Journal:  Cureus       Date:  2019-09-09

5.  Magnetic resonance imaging in the evaluation of cervical foraminal stenosis: comparison of 3D T2 SPACE with sagittal oblique 2D T2 TSE.

Authors:  I Barnaure; J Galley; B Fritz; R Sutter
Journal:  Skeletal Radiol       Date:  2022-01-10       Impact factor: 2.199

6.  T2-Sampling Perfection With Application-Optimized Contrasts by Using Flip Angle Evolution (SPACE) Protocol MRI: A Safe, Minimally Invasive Screening Tool for Spinal CSF Leak Causing Spontaneous Intracranial Hypotension.

Authors:  Bob Daripa; Scott Lucchese
Journal:  Cureus       Date:  2022-07-07

Review 7.  "Wait and scan" management of patients with vestibular schwannoma and the relevance of non-contrast MRI in the follow-up.

Authors:  Jing Zou; Timo Hirvonen
Journal:  J Otol       Date:  2017-08-10

8.  Preliminary study of presumptive intradural-intramedullary intervertebral disc extrusion in 20 dogs.

Authors:  Jaehwan Kim; Hyoju Kim; Jeongyeon Hwang; Kidong Eom
Journal:  J Vet Sci       Date:  2020-07       Impact factor: 1.672

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.