Literature DB >> 28153282

Utilizing online-dual-SPE-LC with HRMS for the simultaneous quantification of amphotericin B, fluconazole, and fluorocytosine in human plasma and cerebrospinal fluid.

Lihua Qu1, Jing Qian2, Ping Ma3, Zheng Yin4.   

Abstract

Amphotericin B (AMB), fluconazole (FZ), and fluorocytosine (FC) are recommended for HIV-associated cryptococcal meningitis (CM) patients as preferred antibiotics. This study presents a fast and automated online-dual-solid phase extraction (SPE)-LC coupled with high resolution mass spectrometer (HRMS) method to simultaneously measure the concentrations of AMB, FZ, and FC in human plasma and cerebrospinal fluid (CSF). Automated sample clean-up was performed on the human plasma and CSF samples with stop-flow heart-cutting two dimensional (2D) separation using a online-dual-SPE system, allowing retention and accumulation of AMB, FZ, and carbamazepine (CBZ, Internal standard (IS)) by the Oasis®HLB cartridge, and retention and accumulation of FC and 5-methylcytosine hydrochloride (MC, IS) by the HyperSep Hypercarb cartridge respectively. Followed by LC elution, quantification by Q-Exactive Hybrid Quadrupole-Orbitrap with targeted-selected ion monitoring (t-SIM) mode was applied to simultaneously determine the concentrations of AMB, FZ and FC. The bioanalysis was achieved in a total running time of 7min. The method was fully validated according to FDA guidelines. The lowest limit of quantification (LLOQ) was 0.04, 0.04, and 0.40μgmL-1 for AMB, FZ, and FC, respectively. AMB, FZ, and FC levels were linear in the ranges of 0.04-2.00μgmL-1, 0.04-2.00μgmL-1 and 0.40-20.00μgmL-1, respectively. The method showed good performance for human plasma and CSF samples with linearity (R2>0.99), intra-day and inter-day precision (relative standard deviation, RSD<4.32% and <4.06%, respectively), recovery (89.93-93.28% and 90.09-93.58%, respectively) and matrix effect (96.35-103.78% and 92.32-101.48%, respectively). The validated method was successfully applied in real samples of Chinese patients. Overall, our results indicate that this fully automated, sensitive, and reliable online-dual-SPE-LC-HRMS method is effective for therapeutic drug monitoring (TDM) of AMB, FZ, and FC levels.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  HIV-CM; Human plasma and CSF; Online-dual-SPE-LC-HRMS; Stop-flow heart-cutting 2D

Mesh:

Substances:

Year:  2016        PMID: 28153282     DOI: 10.1016/j.talanta.2016.12.052

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  A semi-automated, isotope-dilution high-resolution mass spectrometry assay for therapeutic drug monitoring of antidepressants.

Authors:  Johanna M Lindner; Michael Vogeser; Katharina Sorg; Stefanie H Grimm
Journal:  Clin Mass Spectrom       Date:  2019-05-21

2.  Sensitive LC-MS/MS Methods for Amphotericin B Analysis in Cerebrospinal Fluid, Plasma, Plasma Ultrafiltrate, and Urine: Application to Clinical Pharmacokinetics.

Authors:  Leandro Francisco Pippa; Maria Paula Marques; Anna Christina Tojal da Silva; Fernando Crivelenti Vilar; Tissiana Marques de Haes; Benedito Antônio Lopes da Fonseca; Roberto Martinez; Eduardo Barbosa Coelho; Lauro Wichert-Ana; Vera Lucia Lanchote
Journal:  Front Chem       Date:  2021-11-29       Impact factor: 5.221

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.