Reliability and Precision of Sonography of the Lumbar Multifidus and Transversus Abdominis During Dynamic Activities.

Karl C Gibbon1, Dorothee Debuse1, Angela Hibbs1, Nick Caplan1.   

Abstract

OBJECTIVES: To determine the intrarater reliability and precision of lumbar multifidus and transversus abdominis thickness measurements using freehand sonography in a range of static and dynamic conditions.
METHODS: Fifteen asymptomatic participants performed a range of exercises while sonography was used to measure absolute muscle thickness and changes in muscle thickness from rest. Exercise conditions included the abdominal drawing-in maneuver, active straight leg raise, contralateral arm lift, both unloaded and loaded, treadmill walking, and using the Functional Readaptive Exercise Device. Intraday and interday reliability was assessed by intraclass correlation coefficients, and the standard error of measurement was used to assess measurement precision.
RESULTS: Good to excellent reliability was achieved for absolute transversus abdominis and lumbar multifidus thickness in all conditions. Measurement precision for absolute lumbar multifidus thickness was ≤2.8 mm for the unloaded contralateral arm lift, ≤1.8 mm for the loaded contralateral arm lift, ≤3.1 mm for treadmill walking, and ≤3.8 mm for the Functional Readaptive Exercise Device; for absolute transversus abdominis thickness, precision was ≤0.6 mm for the abdominal drawing-in maneuver, ≤0.5 mm for the active straight leg raise, ≤0.7 mm for treadmill walking, and ≤0.5 mm for the Functional Readaptive Exercise Device. Good to excellent reliability was achieved for relative transversus abdominis and lumbar multifidus thickness in all conditions. Measurement precision for relative lumbar multifidus thickness was ≤3.7% for the unloaded contralateral arm lift, ≤3.8% for the loaded contralateral arm lift, ≤6.3% for treadmill walking, and ≤7.6% for the Functional Readaptive Exercise Device; for relative transversus abdominis thickness, precision was ≤13.6% for the abdominal drawing-in maneuver, ≤6.9% for the active straight leg raise, ≤11.1% for treadmill walking, and ≤7.2% for the Functional Readaptive Exercise Device.
CONCLUSIONS: Acceptable reliability and precision of measurement is achieved for absolute and relative measures of deep spinal muscle thickness using freehand sonography in relatively static and dynamic exercises.
© 2017 by the American Institute of Ultrasound in Medicine.

Entities:  

Keywords:  musculoskeletal ultrasound; precision; reliability; sonography; spinal muscles

Mesh:

Year:  2017        PMID: 28150321     DOI: 10.7863/ultra.16.03059

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  3 in total

1.  Transversus Abdominis and Lumbar Multifidus Thickness Among Three Dance Positions in Argentine Tango Dancers.

Authors:  Eleni Gouridou; Eleftherios Kellis; Ermioni Katartzi; Nikolaos Kofotolis
Journal:  Int J Exerc Sci       Date:  2021-04-01

Review 2.  Inconsistent descriptions of lumbar multifidus morphology: A scoping review.

Authors:  Anke Hofste; Remko Soer; Hermie J Hermens; Heiko Wagner; Frits G J Oosterveld; André P Wolff; Gerbrand J Groen
Journal:  BMC Musculoskelet Disord       Date:  2020-05-19       Impact factor: 2.362

3.  The effect of activation of thoracolumbar fascia on the thickness of abdominal muscles: An ultrasonographic study.

Authors:  Zeynep Turan; Özden Özyemişçi-Taşkıran
Journal:  Turk J Phys Med Rehabil       Date:  2022-06-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.