Kursat Er1, Ahmet Ayar2, Omer-Faruk Kalkan3, Sinan Canpolat4, Tamer Tasdemir5, Ulku Ozan6.
Abstract
BACKGROUND: The aim of this study was to investigate the possible neurotoxic effects of 3 root canal sealers (RCSs) (AH Plus, GuttaFlow, iRoot SP) on cultured rat trigeminal ganglion (TG) neurons.Entities:
Year: 2017 PMID: 28149460 PMCID: PMC5268118 DOI: 10.4317/jced.52901
Source DB: PubMed Journal: J Clin Exp Dent ISSN: 1989-5488
Composition and manufacturer of the test sealers.
Figure 1Time- and dose-dependent effects of tested RCSs on cultured rat TG neuron cell number and viability. Cells were incubated for 1, 3, 6 or 24 h in the presence of different sealers or in the absence of any sealers (control), as indicated. Bars represent means (with SD indicated) of three independent experiments. Viability of primary TG neurons was assessed by manual count of viable cells from at least 3 independent preparations, and expressed as mean percentage ± SD.
Figure 3Microscopic image samples. A) control, 0-h. B) control, 24-h, arrows; green: a smaller-sized cell, red: a medium-sized cell, white: a large-sized cell. C) AH Plus, undilue, 1-h. D) AH Plus, dilue, 24-h, arrows; blue: a viable-cell, black: a dead cell, stained, it has been taken into the dye. E) Guttaflow, dilue, 3-h. F) GuttaFlow, undilue, 24-h. G) iRoot SP, dilue, 1-h. and H) iRoot SP, undilue, 24-h.
Figure 2Graphical representation of the diluted and undiluted RCSs together.