Literature DB >> 28149217

Comparison of Barbed Sutures in Porcine Flexor Tenorrhaphy.

Alan Sull1, Serkan Inceoglu1, Alicia August1, Stephen Gregorius2, Montri D Wongworawat1.   

Abstract

Background: Barbed suture use has become more popular as technology and materials have advanced. Minimal data exist regarding performance of the 2 commercially available products, V-LocTM and StratafixTM in tendon repairs. The purpose of this study was to compare gap resistance and ultimate tensile strength of both suture materials and nonbarbed suture in a porcine ex vivo model.
Methods: Porcine flexor tendons were harvested and divided into 3 groups of 10 of varying suture material (3-0 PDS™, 3-0 V- V-Loc 180™, or 3-0 Stratafix™). A modified 4-strand cruciate technique was used to repair each tendon. Knotless repair was performed using barbed suture, whereas a buried 6-throw square knot was done using conventional suture. A servohydrolic tester was used for biomechanical testing of linear 2-mm gap resistance and maximum tensile strength.
Results: No difference was found in 2-mm gap resistance among the 3 groups. No difference was found in ultimate tensile strength between V-Loc™ (76.0 ± 9.4 N) and Stratafix™ (68.1 ± 8.4 N) repairs, but the ultimate strength of the PDS™ control group (83.4 ± 10.0 N) was significantly higher than that of Stratafix™. Conclusions: Barbed (knotless) and nonbarbed suture repairs demonstrate equivalent 2-mm gap resistance. Stratafix™ repairs show slightly inferior performance to nonbarbed repairs in ultimate tensile strength, although this occurred at gap distances far beyond the 2-mm threshold for normal tendon gliding. Both barbed and nonbarbed 4-strand cruciate flexor tendon repairs may require peripheral repair to withstand physiologic loads.

Entities:  

Keywords:  barbed suture; gap; knotless; tendon repair; tensile strength

Mesh:

Year:  2016        PMID: 28149217      PMCID: PMC5256646          DOI: 10.1177/1558944715626928

Source DB:  PubMed          Journal:  Hand (N Y)        ISSN: 1558-9447


  29 in total

1.  The porcine forelimb as a model for human flexor tendon surgery.

Authors:  A M Smith; J A Forder; S R Annapureddy; K S K Reddy; A A Amis
Journal:  J Hand Surg Br       Date:  2005-04-09

2.  Flexor tendon repair: a comparative study between a knotless barbed suture repair and a traditional four-strand monofilament suture repair.

Authors:  C W Joyce; K E Whately; J C Chan; M Murphy; F J O'Brien; S M Carroll
Journal:  J Hand Surg Eur Vol       Date:  2013-05-21

3.  Effect of peripheral suture depth on strength of tendon repairs.

Authors:  E Diao; J S Hariharan; O Soejima; J C Lotz
Journal:  J Hand Surg Am       Date:  1996-03       Impact factor: 2.230

4.  Flexor tendon repair with a knotless barbed suture: a comparative biomechanical study.

Authors:  Ian C Marrero-Amadeo; Aakash Chauhan; Stuart J Warden; Gregory A Merrell
Journal:  J Hand Surg Am       Date:  2011-06-12       Impact factor: 2.230

5.  Influence of locking stitch size in a four-strand cross-locked cruciate flexor tendon repair.

Authors:  Tim S Peltz; Roger Haddad; Peter J Scougall; Sean Nicklin; Mark P Gianoutsos; William R Walsh
Journal:  J Hand Surg Am       Date:  2011-02-17       Impact factor: 2.230

6.  A knotless flexor tendon repair technique using a bidirectional barbed suture: an ex vivo comparison of three methods.

Authors:  W Thomas McClellan; Matthew J Schessler; David S Ruch; L Scott Levin; Richard D Goldner
Journal:  Plast Reconstr Surg       Date:  2011-10       Impact factor: 4.730

7.  Two-, four-, and six-strand zone II flexor tendon repairs: an in situ biomechanical comparison using a cadaver model.

Authors:  R T Thurman; T E Trumble; D P Hanel; A F Tencer; P K Kiser
Journal:  J Hand Surg Am       Date:  1998-03       Impact factor: 2.230

8.  Biomechanical and histologic characteristics of canine flexor tendon repair using early postoperative mobilization.

Authors:  M Aoki; H Kubota; D L Pruitt; P R Manske
Journal:  J Hand Surg Am       Date:  1997-01       Impact factor: 2.230

9.  Zone-II flexor tendon repair: a randomized prospective trial of active place-and-hold therapy compared with passive motion therapy.

Authors:  Thomas E Trumble; Nicholas B Vedder; John G Seiler; Douglas P Hanel; Edward Diao; Sarah Pettrone
Journal:  J Bone Joint Surg Am       Date:  2010-06       Impact factor: 5.284

10.  Tensile strength of flexor tendon repair using barbed suture material in a dynamic ex vivo model.

Authors:  Philip H Zeplin; M Henle; R K Zahn; R H Meffert; K Schmidt
Journal:  J Hand Microsurg       Date:  2012-04-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.