Literature DB >> 28148655

Meta-analysis of gap balancing versus measured resection techniques in total knee arthroplasty.

T Huang1, Y Long2, D George3, W Wang1.   

Abstract

AIMS: There are two techniques widely used to determine the rotational alignment of the components in total knee arthroplasty (TKA); gap balancing (GB) and measured resection (MR). Which technique is the best remains controversial. We aimed to investigate this in a systematic review and meta-analysis.
MATERIALS AND METHODS: In accordance with the methods of Cochrane, databases were searched for all randomised controlled trials in the literature between January 1986 and June 2015 comparing radiographic and clinical outcomes between the use of these two tecniques. Meta-analysis involved the use of the Revman5.3 software provided by Cochrane collaboration.
RESULTS: A total of 1464 papers were initially identified, and after the application of rigourous inclusion and exclusion critera, eight were included in the study. In total they inolved 980 TKAs. The meta-analysis showed that GB techniques resulted in statistically significant improvements in the restoration of mechanical and rotational alignment and mean Knee Society Scores and Knee Society Function scores two years post-operatively, but resulted in greater elevation of the position of the joint line. There is no significant difference in the other radiographic data.
CONCLUSION: This study suggests that GB may provide better radiographic and clinical outcomes than MR when used to determine mechanical rotation in TKAs. Cite this article: Bone Joint J 2017;99-B:151-8. ©2017 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  Gap balancing; Measured resection; Meta-analysis; Total knee arthroplasty

Mesh:

Year:  2017        PMID: 28148655     DOI: 10.1302/0301-620X.99B2.BJJ-2016-0042.R2

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  13 in total

1.  Intraoperative soft tissue balance using novel medial preserving gap technique in posterior-stabilized total knee arthroplasty: comparison to measured resection technique.

Authors:  Kanto Nagai; Hirotsugu Muratsu; Yutaro Kanda; Masanori Tsubosaka; Tomoyuki Kamenaga; Hidetoshi Miya; Takehiko Matsushita; Takahiro Niikura; Ryosuke Kuroda; Tomoyuki Matsumoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-04-21       Impact factor: 4.342

Review 2.  Robotic technology in total knee arthroplasty: a systematic review.

Authors:  Babar Kayani; Sujith Konan; Atif Ayuob; Elliot Onochie; Talal Al-Jabri; Fares S Haddad
Journal:  EFORT Open Rev       Date:  2019-10-01

3.  Bone resection for mechanically aligned total knee arthroplasty creates frequent gap modifications and imbalances.

Authors:  William Blakeney; Yann Beaulieu; Benjamin Puliero; Marc-Olivier Kiss; Pascal-André Vendittoli
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-06-14       Impact factor: 4.342

4.  Gap balancing versus measured resection for primary total knee arthroplasty: a meta-analysis study.

Authors:  Filippo Migliorini; Jörg Eschweiler; Yasser El Mansy; Valentin Quack; Hanno Schenker; Markus Tingart; Arne Driessen
Journal:  Arch Orthop Trauma Surg       Date:  2020-05-14       Impact factor: 3.067

5.  New method for acquiring the expected extension gap in total knee arthroplasty.

Authors:  Hitoshi Sekiya; Kenzo Takatoku; Yuji Kanaya; Hitoshi Okami
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-01-19

6.  Small Improvements in Postoperative Outcome with Gap Balancing Technique Compared with Measured Resection in Total Knee Arthroplasty.

Authors:  Hagen Hommel; Daniel Kunze; Peggy Hommel; Peter Fennema
Journal:  Open Orthop J       Date:  2017-11-10

7.  Comparison of perioperative flurbiprofen axetil or celecoxib administration for pain management after total-knee arthroplasty: A retrospective study.

Authors:  Xia Xiao; Qing Zhang; Zhengxiao Ouyang; Xiaoning Guo
Journal:  Medicine (Baltimore)       Date:  2018-09       Impact factor: 1.817

8.  Cumulative Incidence of Revision for a Balanced Knee System at a Mean 8-Year Follow-Up: A Retrospective Review of 500 Consecutive Total Knee Arthroplasties.

Authors:  Michael H Bourne; Tony L Miller; E Marc Mariani
Journal:  Adv Orthop       Date:  2019-06-02

9.  Robotic total knee arthroplasty: clinical outcomes and directions for future research.

Authors:  B Kayani; F S Haddad
Journal:  Bone Joint Res       Date:  2019-11-02       Impact factor: 5.853

10.  Patient-reported outcome metrics following total knee arthroplasty are influenced differently by patients' body mass index.

Authors:  J M Giesinger; F L Loth; D J MacDonald; K Giesinger; J T Patton; A H R W Simpson; C R Howie; David F Hamilton
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-02-07       Impact factor: 4.342