Comparative Matched Outcome of Evolut-R vs CoreValve Transcatheter Aortic Valve Implantation.

Uri Landes, Tamir Bental, Alon Barsheshet, Abid Assali, Hana Vaknin Assa, Amos Levi, Katia Orvin, Ran Kornowski1.   

Abstract

OBJECTIVES: The Evolut-R (Medtronic, Inc) is a transcatheter aortic valve implantation (TAVI) system that was built on the well-established foundation of Medtronic's CoreValve device platform. Although already in extensive clinical utilization, it is unknown if the Evolut-R improves TAVI outcomes. Herein, we compared TAVI outcomes of the Evolut-R and CoreValve devices.
METHODS: A propensity score 1:1 matching was conducted on 358 Evolut-R patients (n = 75) and CoreValve patients (n = 283). Thirty-day outcomes were compared using Valve Academic Research Consortium (VARC)-2 criteria. A combined 30-day endpoint including all-cause death, stroke, major vascular complication, major bleeding, implantation failure, paravalvular leak (PVL) ≥ moderate, and new pacemaker implantation was also tested.
RESULTS: The final study group included 146 patients (73 Evolut-R; 73 CoreValve). Post matching, baseline characteristics were similar between the two groups. Mean patient age was 82 ± 6 years, mean STS score was 5.2 ± 3.8, 72% were female, and 17% were deemed frail. Implantation success reached 99% with Evolut-R and 94% with CoreValve (P=.10). Both groups had low periprocedural stroke/myocardial infarction/mortality rates and there was also no difference in 30-day vascular complications (P=.18), bleeding (P=.37), PVL (P=.24), and new pacemaker (P=.14). The combined outcome rate was 24% with Evolut-R and 37% with CoreValve (P=.10).
CONCLUSION: This study indicates that the efficacy and safety of the self-expandable second-generation Evolut-R transcatheter valve is at least comparable with the first-generation CoreValve. The observed improved performance in correct positioning of a single valve and the numerically lower chance to suffer a combined TAVI endpoint needs further investigation.

Entities:  

Mesh:

Year:  2017        PMID: 28145874

Source DB:  PubMed          Journal:  J Invasive Cardiol        ISSN: 1042-3931            Impact factor:   2.022


  6 in total

1.  Network meta-analysis of new-generation valves for transcatheter aortic valve implantation.

Authors:  Hisato Takagi; Yosuke Hari; Kouki Nakashima; Toshiki Kuno; Tomo Ando
Journal:  Heart Vessels       Date:  2019-05-29       Impact factor: 2.037

2.  Transcatheter aortic valve replacement using the new Evolut-Pro system: a prospective comparison with the Evolut-R device.

Authors:  Teresa Alvarado; Fernando Rivero; Guillermo Diego; Marcos García-Guimaraes; Jorge Salamanca; Pablo Díez-Villanueva; Javier Cuesta; Paula Antuña; Jesús Jiménez-Borreguero; Fernando Alfonso
Journal:  J Thorac Dis       Date:  2021-07       Impact factor: 2.895

Review 3.  From CoreValve to Evolut PRO: Reviewing the Journey of Self-Expanding Transcatheter Aortic Valves.

Authors:  Dhruv Mahtta; Islam Y Elgendy; Anthony A Bavry
Journal:  Cardiol Ther       Date:  2017-10-27

4.  Transcatheter and Surgical Aortic Valve Replacement in Patients With Previous Cardiac Surgery: A Meta-Analysis.

Authors:  Yi-Ming Li; Jia-Yu Tsauo; Kai-Yu Jia; Yan-Biao Liao; Fan Xia; Zheng-Gang Zhao; Mao Chen; Yong Peng
Journal:  Front Cardiovasc Med       Date:  2021-02-10

5.  Thirty-day incidence of stroke after transfemoral transcatheter aortic valve implantation: meta-analysis and mixt-treatment comparison of self-expandable versus balloon-expandable valve prostheses.

Authors:  Philipp C Seppelt; Silvia Mas-Peiro; Roberta De Rosa; Zisis Dimitriasis; Andreas M Zeiher; Mariuca Vasa-Nicotera
Journal:  Clin Res Cardiol       Date:  2020-11-29       Impact factor: 5.460

6.  Temporal Trends in the Incidence and Outcomes of Pacemaker Implantation After Transcatheter Aortic Valve Replacement in the United States (2012-2017).

Authors:  Akram Kawsara; Samian Sulaiman; Fahad Alqahtani; Mackram F Eleid; Abhishek J Deshmukh; Yong-Mei Cha; Charanjit S Rihal; Mohamad Alkhouli
Journal:  J Am Heart Assoc       Date:  2020-08-31       Impact factor: 5.501

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.