Literature DB >> 28144811

Influence of acquisition orbit on phase analysis of gated single photon emission computed tomography myocardial perfusion imaging for assessment of left ventricular mechanical dyssynchrony.

Tomofumi Misaka1, Makoto Hosono2, Takashi Kudo3, Takamichi Ito1, Tsutomu Syomura1, Masanobu Uemura1, Kaoru Okajima1.   

Abstract

OBJECTIVE: The association between left ventricular (LV) dyssynchrony parameters, given by phase analysis of gated single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI), and acquisition orbits is unclear. The aim of this study was to assess the dependence of LV dyssynchrony parameters on acquisition orbits.
METHODS: Ninety-nine patients who underwent 201Tl-gated SPECT MPI were categorized into minor hypoperfusion or major hypoperfusion groups. Forty-four patients who underwent 99mTc-tetrofosmin-gated SPECT MPI were categorized into minor hypoperfusion or major hypoperfusion groups. The major hypoperfusion group with 201Tl was divided into inferior or non-inferior wall hypoperfusion subgroups, and anteroseptal or non-anteroseptal wall hypoperfusion subgroups. Gated SPECT MPI data over a 360° acquisition orbit (360° images) and a 180° acquisition orbit (180° images) were reconstructed, and histogram bandwidth (HBW) and phase standard deviation (PSD) were compared.
RESULTS: Between 360° and 180° images with 201Tl, there were significant differences in HBW and PSD both globally (HBW 34.8 ± 16.6 vs. 29.1 ± 10.2; PSD 8.8 ± 4.9 vs. 7.0 ± 2.3, p < 0.05 for both) and in the inferior wall (HBW 29.5 ± 15.5 vs. 23.3 ± 9.0; PSD 7.6 ± 4.6 vs. 5.6 ± 2.4, p < 0.001 for both) in the major hypoperfusion group, and also in the inferior wall in all subgroups of the major hypoperfusion group. In contrast, no segment had any significant differences in HBW or PSD between 360° and 180° images with 99mTc.
CONCLUSION: Differences in acquisition orbit had a significant influence on HBW and PSD with 201Tl-gated SPECT MPI in the inferior wall in patients with major hypoperfusion myocardium.

Entities:  

Keywords:  Acquisition orbit; Gated SPECT myocardial perfusion imaging; Left ventricular mechanical dyssynchrony; Phase analysis

Mesh:

Substances:

Year:  2017        PMID: 28144811     DOI: 10.1007/s12149-017-1151-x

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  2 in total

1.  The feasibility of 18F-FDG gated positron emission tomography (PET) for left ventricular dyssynchrony assessment in comparison with 99mTc-MIBI gated single-photon emission computed tomography (SPECT) among patients with prior myocardial infarction.

Authors:  Yong Yao; Tian-Jing Wei; Da-Wei Wang
Journal:  Quant Imaging Med Surg       Date:  2022-04

2.  Fast technetium-99m liver SPECT for evaluation of the pretreatment procedure for radioembolization dosimetry.

Authors:  Sandra van der Velden; Martijn M A Dietze; Max A Viergever; Hugo W A M de Jong
Journal:  Med Phys       Date:  2018-11-13       Impact factor: 4.071

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.