Literature DB >> 28144690

[On the history of cementless implants in extremity surgery].

Pavel Dufek1.   

Abstract

The aim of implantation of cementless hip prostheses is vital ingrowth of bone into the structured metal surface of the implant. Since the 1960s several implants with surfaces made of cobalt-based alloys have been produced for this purpose. In the 1980s a novel hip endoprosthesis with a spongiosa-metal surface was introduced. The three-dimensional ingrowth of bone tissue into the structured surface of the implant could be demonstrated both histologically and using scanning electron microscopy (SEM). These implants made of cobalt-based alloys can also be used in endo-exo prostheses. Titanium implants with a microstructured surface have also been used and very good osseintegration of the surface was also demonstrated by histomorphology. The optimization of the surface and design of the prostheses plays an increasingly more important role in the field of revision endoprostheses.

Entities:  

Keywords:  Biological fixation; Histomorphology; Osseintegration; Spongiosa metal I, II; Titanium implants

Mesh:

Year:  2017        PMID: 28144690     DOI: 10.1007/s00113-016-0293-y

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  5 in total

1.  [Comparative static biomechanical studies of tripod surface structures of cementless endoprostheses].

Authors:  W Mittelmeier; I Grunwald; R Schäfer; E Steinhauser; R Gradinger
Journal:  Z Orthop Ihre Grenzgeb       Date:  1999 Mar-Apr

2.  Determining mineral content variations in bone using backscattered electron imaging.

Authors:  R D Bloebaum; J G Skedros; E G Vajda; K N Bachus; B R Constantz
Journal:  Bone       Date:  1997-05       Impact factor: 4.398

3.  Evaluation of bone ingrowth in proximally and extensively porous-coated anatomic medullary locking prostheses retrieved at autopsy.

Authors:  C A Engh; J P Hooten; K F Zettl-Schaffer; M Ghaffarpour; T F McGovern; J D Bobyn
Journal:  J Bone Joint Surg Am       Date:  1995-06       Impact factor: 5.284

4.  Mechanical consequences of bone ingrowth in a hip prosthesis inserted without cement.

Authors:  T M Keaveny; D L Bartel
Journal:  J Bone Joint Surg Am       Date:  1995-06       Impact factor: 5.284

5.  [Biological fixation and clinical results of the cement-free Lübecker total endoprosthesis made from spongiosa metal].

Authors:  O Sprick; P Dufek
Journal:  Z Orthop Ihre Grenzgeb       Date:  1993 Nov-Dec
  5 in total