Literature DB >> 28143653

Methods, accuracy and clinical implications of atrial fibrillation detection by cardiac implantable electronic devices.

Diana Solari1, Edoardo Bertero1, Roberta Miceli1, Claudio Brunelli1, Pietro Ameri1, Marco Canepa2.   

Abstract

Atrial fibrillation (AF) is the most common arrhythmia in the developed countries and is associated with an increased risk of thromboembolic events and heart failure. Episodes of AF are often asymptomatic and intermittent, eluding diagnosis with non-continuous monitoring techniques. Cardiac implantable electronic devices (CIEDs) represent the gold standard for detecting asymptomatic AF. Improper CIED programming may however increase the risk of false-positive detection of atrial tachyarrhythmias, leading to inappropriate clinical management of patients. A faster rate and a longer duration of the tachyarrhythmic episodes, in addition to a greater AT/AF burden, have been proposed as potential criteria for differentiating between CIED-detected atrial tachyarrhythmias and true AF. Nonetheless, manual overreading of intracardiac electrograms recorded by the CIED remains crucial for a correct diagnosis. Asymptomatic atrial tachyarrhythmias may carry a higher risk of systemic thromboembolism, though clinical thromboembolic risk factors seem to play a greater if not absolute role in prognostication. In addition, there is no clear temporal relationship between CIED-detected atrial tachyarrhythmias and stroke, and the anticoagulation strategy to be pursued in these patients is still a matter of debate and the focus of current prospective randomized studies.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Atrial fibrillation; Atrial tachyarrhythmias; Automatic mode switch; Cardiac implantable electronic device; Stroke; Thromboembolic risk

Mesh:

Year:  2017        PMID: 28143653     DOI: 10.1016/j.ijcard.2016.12.189

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  2 in total

1.  Wireless Endocardial Atrial (and Ventricular) Sensing with no Implanted Power Source: a Proposal.

Authors:  Ivan Corazza; Igor Diemberger; Christian Martignani; Matteo Ziacchi; Pier Luca Rossi; Alessandro Lombi; Romano Zannoli; Mauro Biffi
Journal:  J Med Syst       Date:  2019-04-26       Impact factor: 4.460

2.  Combined Effect of Homocysteine and Uric Acid to Identify Patients With High Risk for Subclinical Atrial Fibrillation.

Authors:  Shihao Wang; Yushan Wei; Tesfaldet Habtemariam Hidru; Daobo Li; Nan Wang; Yiheng Yang; Yunsong Wang; Xiaolei Yang; Yunlong Xia
Journal:  J Am Heart Assoc       Date:  2021-12-31       Impact factor: 5.501

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.