Residual Activity Correction in Quantitative Myocardial Perfusion 13N-Ammonia PET Imaging: A Study in Post-MI Patients.

George Markousis-Mavrogenis1, Luis Eduardo Juárez-Orozco2, Erick Alexanderson3.   

Abstract

BACKGROUND/INTRODUCTION/AIM: Positron emission tomography (PET) is the gold standard for the quantification of myocardial blood flow (MBF). A standard PET scan is acquired in two phases (rest and pharmacological stress). 13N-ammonia is a perfusion radiotracer that may show residual activity, which may affect MBF estimation during the second phase of the scan. An algorithm for residual activity correction (RAC) is available when reconstruction is performed using Syngo MBF (by Siemens). The aim of this study was to evaluate differences in MBF estimation with and without RAC by Syngo MBF in patients with a previous MI using 13N-ammonia PET.
METHODS: MBF was evaluated by 13N-ammonia PET in a group of 25 patients with a history of MI. Dynamic MBF measurements were analyzed with Syngo Dynamic PET, with and without RAC, and the results were evaluated with statistical methods.
RESULTS: Significant differences in stress phase MBF after RAC were identified in the left anterior descending coronary artery (LAD) territory (p=0.0425) and the right coronary artery (RCA) territory (p=0.004). A trend towards significance was identified in the global polar plot (p=0.049). No statistically significant difference was found in the left circumflex artery (LCx) territory (p=0.333).
CONCLUSION: Syngo Dynamic PET, through its RAC function, can be a useful adjunct in assessing second-phase MBF of primarily the RCA territory and secondarily the global polar plot and LAD territory but not the LCx territory.
Copyright © 2017 Hellenic Society of Cardiology. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Coronary arteries; Myocardial perfusion; PET; Residual activity correction; Syngo Dynamic PET

Mesh:

Substances:

Year:  2017        PMID: 28137454     DOI: 10.1016/j.hjc.2016.12.010

Source DB:  PubMed          Journal:  Hellenic J Cardiol        ISSN: 1109-9666


  2 in total

1.  Improved myocardial blood flow estimation with residual activity correction and motion correction in 18F-flurpiridaz PET myocardial perfusion imaging.

Authors:  Yuka Otaki; Serge D Van Kriekinge; Chih-Chun Wei; Paul Kavanagh; Ananya Singh; Tejas Parekh; Marcelo Di Carli; Jamshid Maddahi; Arkadiusz Sitek; Christopher Buckley; Daniel S Berman; Piotr J Slomka
Journal:  Eur J Nucl Med Mol Imaging       Date:  2021-12-30       Impact factor: 10.057

2.  Myocardial blood flow and myocardial flow reserve values in 13N-ammonia myocardial perfusion PET/CT using a time-efficient protocol in patients without coronary artery disease.

Authors:  Opstal Tsj; Knol Rjj; Cornel Jh; Wondergem M; van der Zant Fm
Journal:  Eur J Hybrid Imaging       Date:  2018-06-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.