Literature DB >> 28134586

Blood Bank Specimen Mislabeling: A College of American Pathologists Q-Probes Study of 41 333 Blood Bank Specimens in 30 Institutions.

David A Novis, Paul F Lindholm, Glenn Ramsey, Kirsten W Alcorn, Rhona J Souers, Barbara Blond.   

Abstract

CONTEXT: -Incorrectly labeled patient blood specimens create opportunities for laboratory testing personnel to mistake one patient's specimen for a specimen from a different patient. Transfusion of blood that is typed on specimens that are mislabeled can result in acute hemolytic transfusion reactions.
OBJECTIVE: -To assess the rates of blood bank ABO typing specimens that are mislabeled and/or contain blood belonging to another patient (so-called wrong blood in tube [WBIT]), and to compare these rates with those determined in a similar study performed in 2007.
DESIGN: -Participants enrolled in this College of American Pathologists Q-Probes study for the first quarter of 2015 tallied the number of mislabeled and WBIT ABO blood typing specimens. Outcome measurements were the number of mislabeled and WBIT instances per 1000 specimens. We also evaluated the effects of various practice characteristics, in particular the use of bar coding, on the outcome measurements.
RESULTS: -A total of 30 institutions submitting data on 41 333 ABO blood typing specimens recorded aggregate rates of 7.4 instances of mislabeling (306 specimens) and 0.43 instances of WBIT (10 of 23 234) per 1000 specimens submitted. Mislabeling rates were lower in institutions requiring that specimens be labeled with patients' birth dates than those that did not. The rates of specimen mislabeling and WBIT were otherwise unassociated with any of the other practice variables evaluated.
CONCLUSIONS: -The rates of ABO blood typing specimen mislabeling and WBIT are not statistically different from those determined in a similar study performed in 2007 (P = .94 and P = .10). The use of bar coding was not associated with lower mislabeling (P = .80) or WBIT rates (P = .79).

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28134586     DOI: 10.5858/arpa.2016-0167-CP

Source DB:  PubMed          Journal:  Arch Pathol Lab Med        ISSN: 0003-9985            Impact factor:   5.534


  2 in total

1.  Prevalence of Near-miss Events of Transfusion Practice and Its Associated Factors amongst House Officers in a Teaching Hospital.

Authors:  Noor Haslina Mohd Noor; Kimberly Fe Joibe; Mohd Nazri Hasan
Journal:  Oman Med J       Date:  2021-03-31

2.  Implementation of a blood bank generated tube for second blood group determination: Challenges, yield, and cost.

Authors:  Noora Obaidallah; Helen Downie; Connie Colavecchia; Jeannie Callum; Yulia Lin
Journal:  Transfusion       Date:  2022-02-25       Impact factor: 3.337

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.