Literature DB >> 28131774

High-Sensitivity Troponin Release Profile After Cardiac Surgery.

Phuong L Markman1, John-Paul Tantiongco2, Jayme S Bennetts2, Robert A Baker3.   

Abstract

BACKGROUND: Postoperative serum troponin levels and perioperative myocardial infarction (MI) rates correlate with mortality and morbidity following cardiac surgery. The objective of this study was to document the release profile of high sensitivity troponin T (hsTnT) following different cardiac operations.
METHODS: Patients undergoing one of five different isolated cardiac surgical procedures (eligible preoperative hsTnT <29ng/L, serum creatinine < 0.2mmol/L) were recruited prospectively. Serum hsTnT was measured at 0, 4, 6, 8, 10, 12, 24 and 72hours after the first surgical insult to myocardium, together with daily electrocardiographs.
RESULTS: There were 10 patients in the on-pump coronary artery bypass group and 5 each in the remaining groups (off-pump coronary artery bypass, open aortic valve replacement, transcutaneous aortic valve implantation and mitral valve replacement). Five additional patients were excluded due to perioperative MI or renal failure. Median [range] of peak hsTnT was 241[99-566], 64[50-136], 353[307-902], 115[112-275], and 918[604-1166] ng/L, respectively. Operations with the lowest peak hsTnT values peaked earliest (four hours) while those with highest values peaked latest (eight hours).
CONCLUSION: After cardiac surgery, the hsTnT profile peaks four to eight hours after the initial surgical insult. The magnitude and timing of the peak correlates to the expected degree of surgically-induced myocardial injury.
Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cardiac surgical procedures; Heart valve prosthesis implantation; Myocardial revascularisation; Perioperative period; Troponin; Troponin T

Mesh:

Substances:

Year:  2016        PMID: 28131774     DOI: 10.1016/j.hlc.2016.09.017

Source DB:  PubMed          Journal:  Heart Lung Circ        ISSN: 1443-9506            Impact factor:   2.975


  2 in total

1.  High-sensitivity troponin T release profile in off-pump coronary artery bypass grafting patients with normal postoperative course.

Authors:  Wen Ge; Chang Gu; Chao Chen; Wangwang Chen; Zhengqiang Cang; Yuliang Wang; Chennan Shi; Yangyang Zhang
Journal:  BMC Cardiovasc Disord       Date:  2018-07-31       Impact factor: 2.298

2.  Release Profile of Cardiac Troponin T and Risk Factors of Postoperative Myocardial Injury in Patients Undergoing CABG.

Authors:  Yuying Gu; Lingtong Shan; Ban Liu; Mengwei Lv; Xi Chen; Tao Yan; Yu Shi; Jiapeng Chen; Zhi Li; Yangyang Zhang
Journal:  Int J Gen Med       Date:  2021-06-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.