Recording biosignals without the need for direct skin contact offers new opportunities for ubiquitous health monitoring. Electrodes with capacitive coupling have been shown to be suitable for the monitoring of electrical potentials on the body surface, in particular ECG. However, due to triboelectric charge generation and motion artifacts, signal and thus diagnostic quality is inferior to galvanic coupling. Active closed-loop humidification of capacitive electrodes is proposed in this work as a new concept to improve signal quality. A capacitive ECG recording system integrated into a common car seat is presented. It can regulate the micro climate at the interface of electrode and patient by actively dispensing water vapour and monitoring humidity in a closed-loop approach. As a regenerative water reservoir, silica gel is used. The system was evaluated with respect to subjective and objective ECG signal quality. Active humidification was found to have a significant positive effect in case of previously poor quality. Also, it had no diminishing effect in case of already good signal quality.

Entities:  

Mesh:

Year:  2017        PMID: 28129182     DOI: 10.1109/TBCAS.2016.2613097

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  4 in total

1.  Electrode Humidification Design for Artifact Reduction in Capacitive ECG Measurements.

Authors:  Yue Tang; Ronghui Chang; Limin Zhang; Feng Yan; Haowen Ma; Xiaofeng Bu
Journal:  Sensors (Basel)       Date:  2020-06-18       Impact factor: 3.576

2.  Unobtrusive Vital Sign Monitoring in Automotive Environments-A Review.

Authors:  Steffen Leonhardt; Lennart Leicht; Daniel Teichmann
Journal:  Sensors (Basel)       Date:  2018-09-13       Impact factor: 3.576

Review 3.  Vital Sign Monitoring in Car Seats Based on Electrocardiography, Ballistocardiography and Seismocardiography: A Review.

Authors:  Michaela Sidikova; Radek Martinek; Aleksandra Kawala-Sterniuk; Martina Ladrova; Rene Jaros; Lukas Danys; Petr Simonik
Journal:  Sensors (Basel)       Date:  2020-10-06       Impact factor: 3.576

4.  Applying Noncontact Sensing Technology in the Customized Product Design of Smart Clothes Based on Anthropometry.

Authors:  I-Jan Wang; Wei-Ting Chang; Wen-Hao Wu; Bor-Shyh Lin
Journal:  Sensors (Basel)       Date:  2021-11-29       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.