Literature DB >> 28126458

Impedimetric genosensor for detection of hepatitis C virus (HCV1) DNA using viral probe on methylene blue doped silica nanoparticles.

Chaitali Singhal1, Aviraj Ingle1, Dhritiman Chakraborty1, Anoop Krishna Pn1, C S Pundir2, Jagriti Narang3.   

Abstract

An impedimetric genosensor was fabricated for detection of hepatitis C virus (HCV) genotype 1 in serum, based on hybridization of the probe with complementary target cDNA from sample. To achieve it, probe DNA complementary to HCVgene was immobilized on the surface of methylene blue (MB) doped silica nanoparticles MB@SiNPs) modified fluorine doped tin oxide (FTO) electrode. The synthesized MB@SiNPs was characterized using scanning electron microscopy (SEM), high resolution transmission electron microscopy (HRTEM) and X-ray diffraction (XRD) pattern. This modified electrode (ssDNA/MB@SiNPs/FTO) served both as a signal amplification platform (due to silica nanoparticles (SiNPs) as well as an electrochemical indicator (due to methylene blue (MB)) for the detection of the HCV DNA in patient serum sample. The genosensor was optimized and evaluated. The sensor showed a dynamic linear range 100-106 copies/mL, with a detection limit of 90 copies/mL. The sensor was applied for detection of HCV in sera of hepatitis patient and could be renewed. The half life of the sensor was 4 weeks. The MB@SiNPs/FTO electrode could be used for preparation of other gensensors also.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Electrochemical impedance spectroscopy(EIS); Fluorine doped tin oxide(FTO) electrode; Hepatitis C; Hepatitis C virus (HCV); Impedimetric genosensor; Methylene blue; Probe DNA; Silica nanoparticles; cDNA

Mesh:

Substances:

Year:  2017        PMID: 28126458     DOI: 10.1016/j.ijbiomac.2017.01.093

Source DB:  PubMed          Journal:  Int J Biol Macromol        ISSN: 0141-8130            Impact factor:   6.953


  6 in total

Review 1.  Diagnosis of hepatitis via nanomaterial-based electrochemical, optical or piezoelectrical biosensors: a review on recent advancements.

Authors:  Soodabeh Hassanpour; Behzad Baradaran; Miguel de la Guardia; Amir Baghbanzadeh; Jafar Mosafer; Maryam Hejazi; Ahad Mokhtarzadeh; Mohammad Hasanzadeh
Journal:  Mikrochim Acta       Date:  2018-12-01       Impact factor: 5.833

2.  Electrochemical Biosensor for Sensitive Detection of Hepatitis B in Human Plasma.

Authors:  Ana Cristina Honorato de Castro; Leandro Toshio Kochi; José Manuel Rodrigueiro Flauzino; Márcia Maria Costa Nunes Soares; Valéria Almeida Alves; Luís Antônio da Silva; João Marcos Madurro; Ana Graci Brito-Madurro
Journal:  Appl Biochem Biotechnol       Date:  2022-02-19       Impact factor: 2.926

Review 3.  Genosensors as an alternative diagnostic sensing approaches for specific detection of virus species: A review of common techniques and outcomes.

Authors:  Abouzar Babaei; Amir Pouremamali; Nastaran Rafiee; Hessamaddin Sohrabi; Ahad Mokhtarzadeh; Miguel de la Guardia
Journal:  Trends Analyt Chem       Date:  2022-05-19       Impact factor: 14.908

4.  Morphology-Preferable MoSe2 Nanobrooms as a Sensing Platform for Highly Selective Apta-Capturing of Salmonella Bacteria.

Authors:  Annu Mishra; Jagriti Narang; Chandra Shekhar Pundir; Roberto Pilloton; Manika Khanuja
Journal:  ACS Omega       Date:  2018-10-11

Review 5.  Nanomaterial application in bio/sensors for the detection of infectious diseases.

Authors:  Elham Sheikhzadeh; Valerio Beni; Mohammed Zourob
Journal:  Talanta       Date:  2020-12-17       Impact factor: 6.057

6.  Detection of chikungunya virus DNA using two-dimensional MoS2 nanosheets based disposable biosensor.

Authors:  Chaitali Singhal; Manika Khanuja; Nahid Chaudhary; C S Pundir; Jagriti Narang
Journal:  Sci Rep       Date:  2018-05-16       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.