| Literature DB >> 28125668 |
Grzegorz Borsuk1, Aneta A Ptaszyńska2, Krzysztof Olszewski1, Marcin Domaciuk3, Patcharin Krutmuang4, Jerzy Paleolog5.
Abstract
Bio-analysis of insects is increasingly dependent on highly sensitive methods that require high quality biological material, such as hemolymph. However, it is difficult to collect fresh and uncontaminated hemolymph from adult bees since they are very active and have the potential to sting, and because hemolymph is rapidly melanized. Here we aimed to develop and test a quick and easy method for sterile and contamination-free hemolymph sampling from adult Apidae. Our novel antennae method for hemolymph sampling (AMHS), entailed the detachment of an antenna, followed by application of delicate pressure to the bee's abdomen. This resulted in the appearance of a drop of hemolymph at the base of the detached antenna, which was then aspirated using an automatic pipetter. Larger insect size corresponded to easier and faster hemolymph sampling, and to a greater sample volume. We obtained 80-100 μL of sterile non-melanized hemolymph in 1 minute from one Bombus terrestris worker, in 6 minutes from 10 Apis mellifera workers, and in 15 minutes from 18 Apis cerana workers (+/-0.5 minutes). Compared to the most popular method of hemolymph collection, in which hemolymph is sampled by puncturing the dorsal sinus of the thorax with a capillary (TCHS), significantly fewer bees were required to collect 80-100 μL hemolymph using our novel AMHS method. Moreover, the time required for hemolymph collection was significantly shorter using the AMHS compared to the TCHS, which protects the acquired hemolymph against melanization, thus providing the highest quality material for biological analysis.Entities:
Mesh:
Year: 2017 PMID: 28125668 PMCID: PMC5268409 DOI: 10.1371/journal.pone.0170487
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Fig 1New antenna method of hemolymph collection.
(A) Method for detaching an antenna and inducing hemolymph outflow in a worker honeybee. (B) Collection of hemolymph into a pipette. (C) Microphotograph of hemolymph sampled with the new antennae method (Olympus BX 6; magnification, 500×). (D) Hemolymph samples placed on MRS medium to confirm their sterility (E) Hemolymph samples placed on Sabouraud medium to prove their sterility. (F) Hemolymph circulation in a bee’s body [11].
Characteristics of the new antennae method for hemolymph sampling (AMHS) versus the common method of puncturing the dorsal sinus of the thorax with capillary for hemolymph sampling (TCHS).
| Bee species and caste | Age (days) | Number of bees | Number of individuals needed to obtain 80–100 μl of hemolymph | Sampling time needed to obtain 80–100 μl of hemolymph (+/- 0.5 mins) | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| AMHS | TCHS | AMHS | TCHS | AMHS | TCHS | |||||||
| Mean | SD | Mean | SD | Mean | SD | Mean | SD | |||||
| workers | 10 | 40 | 40 | 10 | 0.20 | 40 | 0.42 | 6 | 0.20 | 15 | 0.12 | |
| drones | 10 | 40 | 40 | 2 | 0.13 | 5 | 0.18 | 1 | 0.12 | 6 | 0.18 | |
| queens | 4 | 20 | 20 | 3 | 0.15 | 6 | 0.19 | 2 | 0.11 | 8 | 0.17 | |
| workers | 10 | 40 | 40 | 18 | 0.12 | 38 | 0.34 | 15 | 0.13 | 40 | 0.38 | |
| workers | - | 40 | 40 | 1 | 0.11 | 3 | 0.17 | 1 | 0.12 | 6 | 0.20 | |
A, B: Capital letters indicate that differences between TCHS and AMHS characteristics are significant at the level of p<0.01 (ANOVA).
a, b: Lowercase letters indicate that differences between TCHS and AMHS characteristics are significant at the level of p<0.05 (ANOVA).
SD: Standard deviation.