| Literature DB >> 28125134 |
Sudhansu Sekhar Sahu1, Kasinathan Gunasekaran1, Kilakootil Narayanan Vijayakumar1, Purushothaman Jambulingam1.
Abstract
BACKGROUND: New brands of potential long lasting insecticide nets (LLINs) and LLIN treatment kits require field evaluation before they are used in a vector control programme.Entities:
Mesh:
Substances:
Year: 2017 PMID: 28125134 PMCID: PMC5293116 DOI: 10.1590/0074-02760160287
Source DB: PubMed Journal: Mem Inst Oswaldo Cruz ISSN: 0074-0276 Impact factor: 2.743
Summary of bioassays and tunnel tests conducted on ICON MAXX long-lasting net treatment and lambda-cyhalothrin ITNs
| Survey (month) | ICON MAXX long-lasting net treatment | Lambda-cyhalothrin ITN | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
| |||||||||||
| Cone bioassay | Tunnel tests | Cone bioassay | Tunnel tests | |||||||||
|
|
|
|
| |||||||||
| No. of nets tested | Mean knock-down (95% CI) | Mean mortality (95% CI) | No. of nets tested | Mean mortality (95% CI) | Mean blood-feeding inhibition (95% CI) | No. of nets tested | Mean knock-down (95% CI) | Mean mortality (95% CI) | No. of nets tested | Mean mortality (95% CI) | Mean blood-feeding inhibition (95% CI) | |
| 1 | 30 | 100.0 | 88.8 (87.9-89.7) | --- | --- | --- | 30 | 100.0 | 92.3 (91.7-92.8) | --- | --- | - |
| 6 | 30 | 100.0 | 100.0 | --- | --- | --- | 30 | 100.0 | 99.7 (99.2-100.3) | --- | --- | - |
| 12 | 30 | 100.0 | 100.0 | --- | --- | --- | 30 | 100.0 | 100.0 | --- | --- | - |
| 18 | 30 | 100.0 | 100.0 | --- | --- | --- | 0 | - | - | - | - | - |
| 24 | 30 | 100.0 | 88.3 (85.8-90.7) | --- | --- | --- | 0 | - | - | - | - | |
| 30 | 30 | 97.3 (95.3-99.4) | 67.5 (57.7-76.3) | 6 | 34.5 (13.8-55.2) | 30.7 (9.9-51.4) | 0 | - | - | - | - | - |
| 36 | 80 | 90.1 (88.5-91.7) | 76.2 (73.1-79.2) | 35 | 41.5 (34.9-48.1) | 29.0 (24.1-33.9) | 0 | - | - | - | - | - |
95% CI: 95% confidence intervals.
% (No nets passing/no. nets tested) ICON MAXX and ITN meeting WHO efficacy criteria in cone and tunnel tests, and their combined pass rate
| Survey (month) | ICON MAXX long-lasting treatment | Lambda-cyhalothrin ITN | ||||
|---|---|---|---|---|---|---|
|
|
| |||||
| Cone bioassays | Tunnel tests | Cone and tunnel tests combined | Cone bioassays | Tunnel tests | Cone and tunnel tests combined | |
| 1 | 100 (30/30) | - | 100 (30/30) | 100 (30/30) | - | 100 (30/30) |
| 6 | 100 (30/30) | - | 100 (30/30) | 100 (30/30) | - | 100 (30/30) |
| 12 | 100 (30/30) | - | 100 (30/30) | 100 (30/30) | - | 100 (30/30) |
| 18 | 100 (30/30) | - | 100 (30/30) | - | - | - |
| 24 | 100 (30/30) | - | 100 (30/30) | - | - | - |
| 30 | 80.0 (24/30) | 0 (0/6) | 80.0 (24/30) | - | - | - |
| 36 | 56.3 (45/80) | 5.7 (2/35) | 58.8 (47/80) | - | - | - |
Usage of LLINs by the households
| Net use | Percentage of use of LLINs after months of distribution | ||||
|---|---|---|---|---|---|
|
| |||||
| 12 (n = 240) | 18 (n = 30) | 24 (n = 180 ) | 30 (n = 30) | 36 (n = 300) | |
| Year - round and every night | 75.8 | 93.3 | 81.1 | 80.0 | 66.7 |
| Year - round occasionally | 7.9 | 0 | 8.9 | 6.7 | 20.7 |
| Seasonally but every night | 7.9 | 0 | 2.8 | 13.3 | 5.3 |
| Seasonally and occasionally | 4.6 | 6.7 | 1.7 | 0 | 0 |
| Not using the net | 3.8 | 0 | 5.6 | 0 | 7.3 |
Washing frequency and appearance of LLINs
| Survey (month) | Number of nets | Mean (SD) number of washes | General aspect of nets (%) | |||
|---|---|---|---|---|---|---|
|
| ||||||
| Clean | Slightly dirty | Very dirty | Dirty | |||
| 1 | 30 | 0 | 83.3 | 13.3 | 3.3 | 0 |
| 6 | 30 | 0.9 (1.1) | 40.0 | 36.7 | 23.3 | 0 |
| 12 | 240 | 1.8 (1.6) | 40.9 | 33.8 | 21.9 | 3.4 |
| 18 | 30 | 1.7 (1.1) | 23.3 | 63.3 | 10.0 | 3.3 |
| 24 | 180 | 4.8 (4.1) | 19.4 | 52.9 | 18.2 | 9.4 |
| 30 | 30 | 4.4 (2.5) | 26.7 | 16.7 | 50.0 | 6.7 |
| 36 | 300 | 8.3 (6.9) | 22.4 | 35.7 | 31.3 | 10.7 |
SD: standard deviation.
Drying practice of LLINs
| Practice | one week | six months | 12 months | 18 months | 24 months | 30 months | 36 months |
|---|---|---|---|---|---|---|---|
|
| |||||||
| LLIN % | LLIN % (n = 14) | LLIN % (n = 191) | LLIN% (n = 28) | LLIN% (n = 166) | LLIN% (n = 29) | LLIN% (n = 268) | |
| Drying under sun | 0 | 85.7 | 52.4 | 85.7 | 72.9 | 51.7 | 63.8 |
| Drying under shade | 0 | 14.3 | 34.0 | 10.7 | 19.3 | 48.3 | 31.3 |
| Inside house | 0 | 0 | 13.6 | 3.6 | 7.8 | 0.0 | 4.9 |
Number of LLINs provided/physically present
| Nets provided/present | one week | six months | 12 months | 18 months | 24 months | 30 months | 36 months |
|---|---|---|---|---|---|---|---|
| No nets provided | 30 | 53 | 454 | 57 | 322 | 55 | 564 |
| No of nets found | 30 | 51 | 435 | 56 | 307 | 50 | 493 |
| Nets lost | 0 | 2 | 19 | 1 | 15 | 5 | 71 |
| Lost (%) | 0 | 3.8 | 4.2 | 1.8 | 4.7 | 9.1 | 12.6 |
Physical integrity of LLINs - estimates of the mean hole index and mean hole area
| Survey (month) | No. of nets surveyed | Hole index mean (± SD) | Hole area cm2 mean (± SD) |
|---|---|---|---|
| 6 | 30 | 13.1 (49.9) | 16.1 (61.2) |
| 12 | 240 | 25.3 (128.8) | 31.0 (158.1) |
| 18 | 30 | 73.6 (137.5) | 90.4 (168.8) |
| 24 | 180 | 72.0 (251.1) | 88.3 (308.3) |
| 30 | 30 | 81.3 (144.8) | 99.8 (177.8) |
| 36 | 300 | 109.1 (304.5) | 133.9 (373.8) |
± SD: standard deviation.
Physical integrity of ICON MAXX long-lasting treatment by survey - holes by distribution
| Survey (month) | No. of nets surveyed | Distribution of holes on net panels (%) | Mean no. of open seams | Nets with any repairs (%) | ||
|---|---|---|---|---|---|---|
|
| ||||||
| Lower | Upper | Roof | ||||
| 1 | 30 | 0 | 0 | 0 | 0 | 0 |
| 6 | 30 | 0 | 67 | 33 | 0.03 | 0 |
| 12 | 240 | 58 | 30 | 12 | 0.1 | 1.3 |
| 18 | 30 | 58 | 35 | 7 | 0.1 | 3.3 |
| 24 | 180 | 53 | 33 | 14 | 0.1 | 1.7 |
| 30 | 30 | 34 | 50 | 16 | 0.2 | 0 |
| 36 | 300 | 47 | 43 | 10 | 0.1 | 2 |