Literature DB >> 28124445

Measurement of B-domain-deleted ReFacto AF activity with a product-specific standard is affected by choice of reagent and patient-specific factors.

M Jacquemin1,2, A Vodolazkaia2, J Toelen2, J Schoeters2, I Van Horenbeeck2, I Vanlinthout2, M Debasse2, K Peerlinck1,3.   

Abstract

INTRODUCTION: Postinfusion ReFacto AF levels can be difficult to measure accurately due to discrepancies between one-stage and chromogenic FVIII assays. To overcome this, the use of the ReFacto AF laboratory standard (RAFLS) is recommended, but there are discordant reports regarding its usefulness. AIM: We investigated whether calibration with RAFLS and measurement of ReFacto AF levels are influenced by the choice of reagents and patient-specific factors in one-stage FVIII assays.
METHODS: Calibration curves were generated with both the RAFLS and a plasma standard using different F8DPs and one-stage FVIII assay reagents. This selection of reagents was then used to determine FVIII levels in the plasma of patients repeatedly treated with ReFacto AF. Results were compared with those obtained with a chromogenic assay.
RESULTS: F8DP devoid of von Willebrand factor (VWF) falsely increased the values of RAFLS pro-coagulant activity generated using the APTT reagent. The resulting RAFLS calibration curve underestimated ReFacto AF levels to be half of their true concentration. The use of RAFLS with F8DP containing VWF reduced the discrepancy observed between the one-stage and chromogenic FVIII assays. However, the mean difference between the two assays still varied up to 50% depending on the patient.
CONCLUSIONS: The RAFLS is a suitable calibrator for one-stage FVIII assays carried out with F8DP containing VWF. However, calibration with the RAFLS does not avoid the effect of patient-specific variables that contribute to discrepancies between the measurements of ReFacto AF levels with one-stage and chromogenic FVIII assays.
© 2017 John Wiley & Sons Ltd.

Entities:  

Keywords:  ReFacto AF; chromogenic FVIII assay; factor VIII; moroctocog alfa-AF; one-stage FVIII assay; von Willebrand factor

Mesh:

Substances:

Year:  2017        PMID: 28124445     DOI: 10.1111/hae.13123

Source DB:  PubMed          Journal:  Haemophilia        ISSN: 1351-8216            Impact factor:   4.287


  1 in total

Review 1.  Position paper on laboratory testing for patients with haemophilia. A consensus document from SISET, AICE, SIBioC and SIPMeL.

Authors:  Armando Tripodi; Rita C Santoro; Sophie Testa; Angelo C Molinari; Sergio Bernardini; Maria Golato; Giuseppe Lippi; Walter Ageno; Elena Santagostino
Journal:  Blood Transfus       Date:  2019-02-04       Impact factor: 3.443