Literature DB >> 28123153

Efficacy of the Stonehenge Technique for Minimally Invasive Aortic Valve Replacement via Right Infraaxillary Thoracotomy.

Masataka Yamazaki1, Hajime Kin, Shohei Kitamoto, Shota Yamanaka, Hidefumi Nishida, Kosaku Nishigawa, Shuichiro Takanashi.   

Abstract

Minimally invasive cardiac surgeries for aortic valve replacement (AVR) are still a technical challenge for surgeons because these procedures are undertaken through small incisions and deep surgical fields. Although AVR via vertical infraaxillary thoracotomy can be a cosmetically superior option, a disadvantage of this approach is the distance between the thoracotomy incision and the ascending aorta. Therefore, we devised a technique to perform all manipulations using the fingertips without the aid of a knot pusher or long-shafted surgical instruments. This was achieved by particular placement of several retracted sutures to the right chest wall. We named placement of these sutures the "Stonehenge technique." In conclusion, AVR via vertical infraaxillary thoracotomy with our Stonehenge technique can be safely and simply performed with superior cosmetic advantages.

Mesh:

Year:  2017        PMID: 28123153      PMCID: PMC5347488          DOI: 10.5761/atcs.nm.16-00248

Source DB:  PubMed          Journal:  Ann Thorac Cardiovasc Surg        ISSN: 1341-1098            Impact factor:   1.520


  2 in total

Review 1.  Right infra-axillary mini-thoracotomy for aortic valve replacement.

Authors:  Toshiaki Ito; Atsuo Maekawa; Satoshi Hoshino; Yasunari Hayashi
Journal:  Ann Cardiothorac Surg       Date:  2015-01

2.  Right infraaxillary thoracotomy for minimally invasive aortic valve replacement.

Authors:  Toshiaki Ito; Atsuo Maekawa; Satoshi Hoshino; Yasunari Hayashi
Journal:  Ann Thorac Surg       Date:  2013-08       Impact factor: 4.330

  2 in total
  2 in total

1.  Stonehenge technique is associated with faster aortic clamp time in group of minimally invasive aortic valve replacement via right infra-axillary thoracotomy.

Authors:  Masataka Yamazaki; Akihiro Yoshitake; Tatsuo Takahashi; Tsutomu Ito; Naritaka Kimura; Akinori Hirano; Yasunori Iida; Shuichiro Takanashi; Hideyuki Shimizu
Journal:  Gen Thorac Cardiovasc Surg       Date:  2018-08-16

2.  Safety and Applicability of Continuous Retrograde Cardioplegia in Minimally Invasive Aortic Valve Replacement: New Approaches.

Authors:  Shunsuke Sato; Takashi Azami; Tatsuya Kawamoto; Kyozo Inoue; Kenji Okada
Journal:  Ann Thorac Cardiovasc Surg       Date:  2021-08-04       Impact factor: 1.520

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.