Literature DB >> 28118149

Assessment of the occupational eye lens dose for clinical staff in interventional radiology, cardiology and neuroradiology.

Artur Omar1, Nils Kadesjö, Charlotta Palmgren, Maria Marteinsdottir, Tony Segerdahl, Annette Fransson.   

Abstract

In accordance with recommendations by the International Commission on Radiological Protection, the current European Basic Safety Standards has adopted a reduced occupational eye lens dose limit of 20 mSv yr-1. The radiation safety implications of this dose limit is of concern for clinical staff that work with relatively high dose x-ray angiography and interventional radiology. Presented in this work is a thorough assessment of the occupational eye lens dose based on clinical measurements with active personal dosimeters worn by staff during various types of procedures in interventional radiology, cardiology and neuroradiology. Results are presented in terms of the estimated equivalent eye lens dose for various medical professions. In order to compare the risk of exceeding the regulatory annual eye lens dose limit for the widely different clinical situations investigated in this work, the different medical professions were separated into categories based on their distinct work pattern: staff that work (a) regularly beside the patient, (b) in proximity to the patient and (c) typically at a distance from the patient. The results demonstrate that the risk of exceeding the annual eye lens dose limit is of concern for staff category (a), i.e. mainly the primary radiologist/cardiologist. However, the results also demonstrate that the risk can be greatly mitigated if radiation protection shields are used in the clinical routine. The results presented in this work cover a wide range of clinical situations, and can be used as a first indication of the risk of exceeding the annual eye lens dose limit for staff at other medical centres.

Entities:  

Mesh:

Year:  2017        PMID: 28118149     DOI: 10.1088/1361-6498/aa559c

Source DB:  PubMed          Journal:  J Radiol Prot        ISSN: 0952-4746            Impact factor:   1.394


  3 in total

1.  A study to assess the knowledge and practice of medical professionals on radiation protection in interventional radiology.

Authors:  Mohsen Shafiee; Razieh Rashidfar; Jamil Abdolmohammadi; Sajad Borzoueisileh; Zaker Salehi; Kheibar Dashtian
Journal:  Indian J Radiol Imaging       Date:  2020-03-30

Review 2.  Occupational radiation exposure to nursing staff during cardiovascular fluoroscopic procedures: A review of the literature.

Authors:  Kelly Wilson-Stewart; Madeleine Shanahan; Davide Fontanarosa; Rob Davidson
Journal:  J Appl Clin Med Phys       Date:  2018-10-08       Impact factor: 2.102

3.  Taller staff occupationally exposed to less radiation to the temple in cardiac procedures, but risk higher doses during vascular cases.

Authors:  Kelly S Wilson-Stewart; Davide Fontanarosa; Dan Li; Chris C Drovandi; Rebecca K Anderson; Jamie V Trapp
Journal:  Sci Rep       Date:  2020-09-30       Impact factor: 4.379

  3 in total