Literature DB >> 28117793

Topical Airway Anesthesia for Awake-endoscopic Intubation Using the Spray-as-you-go Technique with High Oxygen Flow.

Nina Pirlich1, Jana A Lohse1, Rüdiger R Noppens2.   

Abstract

A patient's willingness to cooperate is an absolute precondition for successful awake intubation of the trachea. Whilst drug-sedation of patients can jeopardize their spontaneous breathing, topical anesthesia of the airway is a popular technique. The spray-as-you-go technique represents one of the simplest opportunities to anesthetize the airway mucosa. The application of local anesthetic through the working channel of the flexible endoscope is a widespread practice for anesthetists as well as pulmonologists. There is neither need for additional devices nor special training as a pre-requisite to perform this technique. However, a known clinical problem is the coughing and gagging reflex that may occur when the liquid anesthetic strikes the airway mucosa and other sensitive structures like the vocal cords. This can be avoided by the use of oxygen applied through the working channel with the aim of fogging the local anesthetic into finer particles. Furthermore, the oxygen flow provides a higher oxygen supply and contributes to a better view, dispersing mucus secretions and blood away from the lens. Using an atomizer with a high oxygen flow of 10 L/min we maximized these benefits, caused less coughing and had more satisfied and therefore cooperative patients. Possible, but very rare complications of using oxygen flow including gastric insufflation, organ rupture or barotrauma did not arise. We attribute the complication-free use of high oxygen flow to the design of the set, which permits flow and pressure release.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28117793      PMCID: PMC5352221          DOI: 10.3791/55116

Source DB:  PubMed          Journal:  J Vis Exp        ISSN: 1940-087X            Impact factor:   1.355


  13 in total

1.  A method of administering topical anaesthesia for flexible airway endoscopy.

Authors:  D O'Hare; R Harwood; N Woodall; G Barker
Journal:  Anaesthesia       Date:  2000-06       Impact factor: 6.955

Review 2.  Airway regional anesthesia for awake fiberoptic intubation.

Authors:  Shawn T Simmons; Arno R Schleich
Journal:  Reg Anesth Pain Med       Date:  2002 Mar-Apr       Impact factor: 6.288

3.  Combined nebulization and spray-as-you-go topical local anaesthesia of the airway.

Authors:  K A Williams; G L Barker; R J Harwood; N M Woodall
Journal:  Br J Anaesth       Date:  2005-08-26       Impact factor: 9.166

4.  An alternative to transtracheal injection for fiberoptic intubation in awake patients: a novel noninvasive technique using a standard multiorifice epidural catheter through the bronchoscope suction port.

Authors:  Timothy R Long; C Thomas Wass
Journal:  Anesthesiology       Date:  2004-11       Impact factor: 7.892

5.  Gastric rupture and pneumoperitoneum caused by oxygen insufflation via a fiberoptic bronchoscope.

Authors:  Niels Chapman
Journal:  Anesth Analg       Date:  2008-05       Impact factor: 5.108

6.  Gastric distention and rupture from oxygen insufflation during fiberoptic intubation.

Authors:  M D Hershey; A A Hannenberg
Journal:  Anesthesiology       Date:  1996-12       Impact factor: 7.892

7.  Gastric rupture after awake fibreoptic intubation in a patient with laryngeal carcinoma.

Authors:  C-M Ho; I-W Yin; K-F Tsou; L-H Chow; S-K Tsai
Journal:  Br J Anaesth       Date:  2005-03-11       Impact factor: 9.166

8.  A comparison of the Enk Fiberoptic Atomizer Set(™) with boluses of topical anaesthesia for awake fibreoptic intubation.

Authors:  N Pirlich; J A Lohse; I Schmidtmann; N Didion; T Piepho; R R Noppens
Journal:  Anaesthesia       Date:  2016-05-06       Impact factor: 6.955

9.  Comparison of Enk Fibreoptic Atomizer with translaryngeal injection for topical anaesthesia for awake fibreoptic intubation in patients at risk of secondary cervical injury: A randomised controlled trial.

Authors:  Michael J Malcharek; Manuel Bartz; Birgit Rogos; Lutz Günther; Armin Sablotzki; Jochen Gille; Gerhard Schneider
Journal:  Eur J Anaesthesiol       Date:  2015-09       Impact factor: 4.330

10.  Comparison of two different techniques of fibreoptic intubation.

Authors:  Tim Piepho; Andreas R Thierbach; Susanne M Göbler; Marc O Maybauer; Christian Werner
Journal:  Eur J Anaesthesiol       Date:  2009-04       Impact factor: 4.330

View more
  4 in total

1.  Awake fiberoptic orotracheal intubation: a protocol feasibility study.

Authors:  Yuanyuan Ma; Xue Cao; Hong Zhang; Shengjin Ge
Journal:  J Int Med Res       Date:  2021-01       Impact factor: 1.671

2.  A Prospective Observational Comparison of Two Approaches to Anesthetizing the Trachea for Awake Intubation.

Authors:  Thomas M McCutchen; Kathleen N Johnson; Jacob G Fowler; Jessica E Fanelli; Saskia C Anzola; Sarah J Bost; Thomas W Templeton; Amit K Saha
Journal:  Cureus       Date:  2022-02-21

3.  Management of video-assisted thoracoscopic (VATs) bilateral cardiac sympathectomy in refractory ventricular storm: A case report.

Authors:  Gayatri R Sakrikar; Madhavi Buddhi; R D Patel; Shraddha S Mathkar
Journal:  Ann Card Anaesth       Date:  2022 Jan-Mar

4.  Lidocaine-eluting endotracheal tube effectively attenuates intubation related airway response.

Authors:  Jing Lu; Wenjie Tian; Linxian Cui; Bing Cai; Tingting Zhang; Nan Huang; Lei Lu; Tao Zhu
Journal:  Ann Transl Med       Date:  2021-05
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.