AIMS: Pacemaker lead-associated severe tricuspid regurgitation (TR) can lead to right heart failure and poor prognosis. Surgery in these patients carries significant morbidities. We describe a successful treatment of symptomatic severe TR by leadless pacemaker implantation followed by tricuspid valve (TV) repair with the MitraClip NT. METHODS AND
RESULTS: A 71-year-old frail female with poor functional status, chronic atrial fibrillation and permanent pacemaker implantation in 2012 presented with symptomatic moderate-severe mitral regurgitation (MR) and severe TR with the pacemaker lead as the culprit. She was deemed extreme risk for double valve surgery and, because of her pacemaker dependency, the decision was to stage her interventions first with transcatheter mitral repair, then laser lead extraction and leadless pacemaker implantation to free the TV from tethering, then TV repair. An obstructive LAD lesion was identified and treated during mitral repair with the MitraClip NT. The Micra leadless pacemaker implantation and subsequent TV repair with the MitraClip NT were successful and the patient's MR improved to mild and TR to moderate, respectively.
CONCLUSIONS: We report here a first successful transcatheter strategy to treat lead-associated severe TR by leadless pacemaker and MitraClip. Removing the pacemaker lead relieved leaflet tethering and improved the reparability of the TV.

Entities:  

Mesh:

Year:  2017        PMID: 28117279     DOI: 10.4244/EIJ-D-17-00023

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  2 in total

1.  Single- and dual-site ventricular pacing entirely through the coronary sinus for patients with prior tricuspid valve surgery.

Authors:  Chin C Lee; Khuyen Do; Sati Patel; Steven K Carlson; Tomas Konecny; Philip M Chang; Rahul N Doshi
Journal:  J Interv Card Electrophysiol       Date:  2019-08-20       Impact factor: 1.900

2.  Leadless pacemaker through tricuspid bioprosthetic valve: Early experience.

Authors:  Giovanni Morani; Bruna Bolzan; Antonio Pepe; Flavio Luciano Ribichini
Journal:  J Arrhythm       Date:  2021-01-22
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.