Literature DB >> 28113322

Comparison of Constant-Posture Force-Varying EMG-Force Dynamic Models About the Elbow.

Chenyun Dai, Berj Bardizbanian, Edward A Clancy.   

Abstract

Numerous techniques have been used to minimize error in relating the surface electromyogram (EMG) to elbow joint torque. We compare the use of three techniques to further reduce error. First, most EMG-torque models only use estimates of EMG standard deviation as inputs. We studied the additional features of average waveform length, slope sign change rate and zero crossing rate. Second, multiple channels of EMG from the biceps, and separately from the triceps, have been combined to produce two low-variance model inputs. We contrasted this channel combination with using each EMG separately. Third, we previously modeled nonlinearity in the EMG-torque relationship via a polynomial. We contrasted our model versus that of the classic exponential power law of Vredenbregt and Rau (1973). Results from 65 subjects performing constant-posture, force-varying contraction gave a "baseline" comparison error (i.e., error with none of the new techniques) of 5.5 ± 2.3% maximum flexion voluntary contraction (%MVCF). Combining the techniques of multiple features with individual channels reduced error to 4.8 ± 2.2 %MVCF, while combining individual channels with the power-law model reduced error to 4.7 ± 2.0 %MVCF. The new techniques further reduced error from that of the baseline by ≈ 15 %.

Mesh:

Year:  2016        PMID: 28113322     DOI: 10.1109/TNSRE.2016.2639443

Source DB:  PubMed          Journal:  IEEE Trans Neural Syst Rehabil Eng        ISSN: 1534-4320            Impact factor:   3.802


  5 in total

1.  Motor unit drive: a neural interface for real-time upper limb prosthetic control.

Authors:  Michael D Twardowski; Serge H Roy; Zhi Li; Paola Contessa; Gianluca De Luca; Joshua C Kline
Journal:  J Neural Eng       Date:  2018-10-24       Impact factor: 5.379

2.  Two degrees of freedom quasi-static EMG-force at the wrist using a minimum number of electrodes.

Authors:  Edward A Clancy; Carlos Martinez-Luna; Marek Wartenberg; Chenyun Dai; Todd R Farrell
Journal:  J Electromyogr Kinesiol       Date:  2017-03-29       Impact factor: 2.368

3.  Two degrees of freedom, dynamic, hand-wrist EMG-force using a minimum number of electrodes.

Authors:  Chenyun Dai; Ziling Zhu; Carlos Martinez-Luna; Thane R Hunt; Todd R Farrell; Edward A Clancy
Journal:  J Electromyogr Kinesiol       Date:  2019-04-16       Impact factor: 2.368

4.  EMG-Force and EMG-Target Models During Force-Varying Bilateral Hand-Wrist Contraction in Able-Bodied and Limb-Absent Subjects.

Authors:  Ziling Zhu; Carlos Martinez-Luna; Jianan Li; Benjamin E McDonald; Chenyun Dai; Xinming Huang; Todd R Farrell; Edward A Clancy
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2021-01-28       Impact factor: 3.802

5.  Myoelectric Control Performance of Two Degree of Freedom Hand-Wrist Prosthesis by Able-Bodied and Limb-Absent Subjects.

Authors:  Ziling Zhu; Jianan Li; William J Boyd; Carlos Martinez-Luna; Chenyun Dai; Haopeng Wang; He Wang; Xinming Huang; Todd R Farrell; Edward A Clancy
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2022-04-11       Impact factor: 4.528