Literature DB >> 28112650

Inclusion of thin target and source regions in alimentary and respiratory tract systems of mesh-type ICRP adult reference phantoms.

Han Sung Kim1, Yeon Soo Yeom, Thang Tat Nguyen, Chansoo Choi, Min Cheol Han, Jai Ki Lee, Chan Hyeong Kim, Maria Zankl, Nina Petoussi-Henss, Wesley E Bolch, Choonsik Lee, Rui Qiu, Keith Eckerman, Beom Sun Chung.   

Abstract

It is not feasible to define very small or complex organs and tissues in the current voxel-type adult reference computational phantoms of the International Commission on Radiological Protection (ICRP), which limit dose coefficients for weakly penetrating radiations. To address the problem, the ICRP is converting the voxel-type reference phantoms into mesh-type phantoms. In the present study, as a part of the conversion project, the micrometer-thick target and source regions in the alimentary and respiratory tract systems as described in ICRP Publications 100 and 66 were included in the mesh-type ICRP reference adult male and female phantoms. In addition, realistic lung airway models were simulated to represent the bronchial (BB) and bronchiolar (bb) regions. The electron specific absorbed fraction (SAF) values for the alimentary and respiratory tract systems were then calculated and compared with the values calculated with the stylized models of ICRP Publications 100 and 66. The comparisons show generally good agreement for the oral cavity, oesophagus, and BB, whereas for the stomach, small intestine, large intestine, extrathoracic region, and bb, there are some differences (e.g. up to ~9 times in the large intestine). The difference is mainly due to anatomical difference in these organs between the realistic mesh-type phantoms and the simplified stylized models. The new alimentary and respiratory tract models in the mesh-type ICRP reference phantoms preserve the topology and dimensions of the voxel-type ICRP phantoms and provide more reliable SAF values than the simplified models adopted in previous ICRP Publications.

Entities:  

Mesh:

Year:  2017        PMID: 28112650     DOI: 10.1088/1361-6560/aa5b72

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  2 in total

Review 1.  An update on computational anthropomorphic anatomical models.

Authors:  Azadeh Akhavanallaf; Hadi Fayad; Yazdan Salimi; Antar Aly; Hassan Kharita; Huda Al Naemi; Habib Zaidi
Journal:  Digit Health       Date:  2022-07-11

2.  Individualized adjustments to reference phantom internal organ dosimetry-scaling factors given knowledge of patient internal anatomy.

Authors:  Michael B Wayson; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2018-04-13       Impact factor: 3.609

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.