Literature DB >> 28112018

Reversed Frozen Elephant Trunk Technique to Treat a Type II Thoracoabdominal Aortic Aneurysm.

E Sebastian Debus1, Tilo Kölbel1, Sabine Wipper1, Holger Diener1, Beate Reiter2, Christian Detter2, Nikolaos Tsilimparis1.   

Abstract

PURPOSE: To describe a hybrid technique of reversed frozen elephant trunk to treat thoracoabdominal aortic aneurysms (TAAA) through an abdominal only approach. TECHNIQUE: The technique is demonstrated in a 29-year-old Marfan patient with a chronic type B aortic dissection previously treated with a thoracic stent-graft who presented with a thoracoabdominal false lumen aneurysm. Through an open distal retroperitoneal approach to the abdominal aorta, a frozen elephant trunk graft was implanted over a super-stiff wire upside down with the stent-graft component in the thoracic aorta. Following deployment of the stent-graft proximally and preservation of renovisceral perfusion in a retrograde manner, the renovisceral vessels were sequentially anastomosed to the elephant trunk graft branches, thus reducing the ischemia time of the end organs. The aortic sac was then opened, and the distal part of the hybrid graft was anastomosed with a further bifurcated graft to the iliac vessels.
CONCLUSION: The reversed frozen elephant trunk technique is feasible for hybrid treatment of TAAAs via an abdominal approach only. This has the benefit of substantially reducing the trauma of thoracic exposure, thus preserving major benefits of open thoracoabdominal surgery, such as the presence of short bypasses to the renovisceral vessels and reimplantation of lumbar arteries to reduce spinal cord ischemia.

Entities:  

Keywords:  bypass graft; hybrid procedure; renovisceral vessels; retroperitoneal approach; reversed frozen elephant trunk prosthesis; stent-graft; thoracic endovascular aortic repair; thoracoabdominal aortic aneurysm

Mesh:

Year:  2016        PMID: 28112018     DOI: 10.1177/1526602816678992

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  1 in total

1.  Single-Center Experience With the Thoraflex™ Hybrid Prosthesis: Indications, Implantation Technique and Results.

Authors:  Konrad Wisniewski; Arash Motekallemi; Angelo M Dell'Aquila; Alexander Oberhuber; Johannes F Schaefers; Abdulhakim Ibrahim; Sven Martens; Andreas Rukosujew