Literature DB >> 28109874

Comparison of Durable-Polymer Zotarolimus-Eluting and Biodegradable-Polymer Biolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease: 3-Year Clinical Outcomes in the Randomized SORT OUT VI Trial.

Bent Raungaard1, Evald H Christiansen2, Hans Erik Bøtker2, Henrik S Hansen3, Jan Ravkilde4, Leif Thuesen4, Jens Aarøe4, Anton B Villadsen4, Christian J Terkelsen2, Lars R Krusell2, Michael Maeng2, Steen D Kristensen2, Karsten T Veien3, Knud N Hansen3, Anders Junker3, Morten Madsen5, Søren L Andersen5, Svend E Jensen4, Lisette O Jensen3.   

Abstract

OBJECTIVES: The authors sought to compare the safety and efficacy of the biocompatible durable-polymer zotarolimus-eluting stent with the biodegradable-polymer biolimus-eluting stent in unselected coronary patients.
BACKGROUND: Biodegradable-polymer biolimus-eluting stents are superior to first-generation durable-polymer drug-eluting stents in long-term randomized all-comer trials. Long-term data comparing them to second-generation durable-polymer drug-eluting stents are lacking.
METHODS: The study was a randomized, multicenter, all-comer, noninferiority trial in patients with chronic stable coronary artery disease or acute coronary syndromes and at least 1 coronary artery lesion requiring treatment with a drug-eluting stent. Endpoints included major adverse cardiac events (MACE), a composite of safety (cardiac death and myocardial infarction not clearly attributable to a non-target lesion) and efficacy (target lesion revascularization); the individual endpoints of MACE; all-cause mortality; any myocardial infarction; target vessel revascularization; and definite or probable stent thrombosis at 36 months.
RESULTS: From March 2011 to August 2012, 2,999 patients were randomly assigned (1:1) to receive either the zotarolimus-eluting (1,502 patients) or the biolimus-eluting (1,497 patients) stent. At 3-year follow-up, MACE occurred in 128 (8.6%) patients assigned to the durable-polymer zotarolimus-eluting stent and in 144 (9.6%) assigned to the biodegradable-polymer biolimus-eluting stent (p = 0.36). Occurrence of cardiac death (2.7% vs. 3.4%), myocardial infarction not clearly attributable to a non-target lesion (2.7% vs. 2.5%), and target lesion revascularization (5.4% vs. 5.5%) did not differ significantly between the 2 groups. Definite very late stent thrombosis occurred in 6 (0.4%) patients assigned to the durable-polymer zotarolimus-eluting stent and in 10 (0.7%) assigned to the biodegradable-polymer biolimus-eluting stent (p = 0.33).
CONCLUSIONS: At 3-year follow-up, the durable-polymer zotarolimus-eluting stent and the biodegradable-polymer biolimus-eluting stent were similar in clinical outcome, with no significant difference in safety and efficacy outcomes, including stent thrombosis.
Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  biolimus; drug-eluting; polymer; randomized clinical trial; stent; zotarolimus

Mesh:

Substances:

Year:  2017        PMID: 28109874     DOI: 10.1016/j.jcin.2016.11.007

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  5 in total

Review 1.  The Newest Generation of Drug-eluting Stents and Beyond.

Authors:  Dae-Hyun Lee; Jose M de la Torre Hernandez
Journal:  Eur Cardiol       Date:  2018-08

2.  CVIT expert consensus document on primary percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI) in 2018.

Authors:  Yukio Ozaki; Yuki Katagiri; Yoshinobu Onuma; Tetsuya Amano; Takashi Muramatsu; Ken Kozuma; Satoru Otsuji; Takafumi Ueno; Nobuo Shiode; Kazuya Kawai; Nobuhiro Tanaka; Kinzo Ueda; Takashi Akasaka; Keiichi Igarashi Hanaoka; Shiro Uemura; Hirotaka Oda; Yoshiaki Katahira; Kazushige Kadota; Eisho Kyo; Katsuhiko Sato; Tadaya Sato; Junya Shite; Koichi Nakao; Masami Nishino; Yutaka Hikichi; Junko Honye; Tetsuo Matsubara; Sumio Mizuno; Toshiya Muramatsu; Taku Inohara; Shun Kohsaka; Ichiro Michishita; Hiroyoshi Yokoi; Patrick W Serruys; Yuji Ikari; Masato Nakamura
Journal:  Cardiovasc Interv Ther       Date:  2018-03-29

3.  Biodegradable polymer versus second-generation durable polymer drug-eluting stents in patients with coronary artery disease: A meta-analysis.

Authors:  James J Wu; Joshua A H Way; Probal Roy; Andy Yong; Harry Lowe; Leonard Kritharides; David Brieger
Journal:  Health Sci Rep       Date:  2018-10-05

4.  High Bleeding Risk Patients Treated with Very Thin-Strut Biodegradable Polymer or Thin-Strut Durable Polymer Drug-Eluting Stents in the BIO-RESORT Trial.

Authors:  Paolo Zocca; Marlies M Kok; Liefke C van der Heijden; Peter W Danse; Carl E Schotborgh; Martijn Scholte; Marc Hartmann; Gerard C M Linssen; Carine J M Doggen; Clemens von Birgelen
Journal:  Cardiovasc Drugs Ther       Date:  2018-12       Impact factor: 3.727

5.  Biodegradable polymer drug-eluting stents versus second-generation drug-eluting stents in patients with and without diabetes mellitus: a single-center study.

Authors:  Xiao-Fang Tang; Yuan-Liang Ma; Ying Song; Jing-Jing Xu; Yi Yao; Chen He; Huan-Huan Wang; Ping Jiang; Lin Jiang; Ru Liu; Zhan Gao; Xue-Yan Zhao; Shu-Bin Qiao; Yue-Jin Yang; Run-Lin Gao; Bo Xu; Jin-Qing Yuan
Journal:  Cardiovasc Diabetol       Date:  2018-08-14       Impact factor: 9.951

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.