Literature DB >> 28109057

Comparison of two biodegradable-polymer-based sirolimus-eluting stents with varying elution and absorption kinetics in patients with acute myocardial infarction: A subgroup analysis of the PANDA III trial.

Changdong Guan1, Bo Xu1, Shubin Qiao1, Lei Qin2, Yi Li3, Zhanquan Li4, Yong Guo5, Zhongwei Sun1, Lei Song1, Runlin Gao1.   

Abstract

BACKGROUND: Implantation of early-generation metallic drug-eluting stents (DES) in patients with acute myocardial infarction (AMI) is associated with poor vessel wall healing. Use of biodegradable polymer (BP) DES might improve safety outcomes; however, the impact of varying drug elution and polymer absorption kinetics of BP-DES on clinical outcomes in the AMI population is unknown.
METHODS: This subgroup analysis of the randomized PANDA III trial included 732 patients (366 in each group) presenting with recent (<1 month) AMI. Primary endpoint was 1-year target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (MI), or ischemia-driven target lesion revascularization. Secondary endpoints included a patient-oriented composite endpoint (PoCE) of all-cause death, all MI, or any revascularization; individual TLF and PoCE components; and definite/probable stent thrombosis (ST).
RESULTS: There were no significant differences between-groups in baseline clinical, angiographic, or procedural characteristics other than the proportion of post-dilatation, which was performed more frequently with the BuMA stent (53.9% vs. 44.5%; P = 0.004). After 1 year, compared to Excel SES implantation in patients with AMI, BuMA was associated with similar incidences of TLF and PoCE (5.5% vs. 8.3%, P = 0.14; 8.8% vs. 9.9%, P = 0.61, respectively) but lower incidences of MI (2.5% vs. 6.1%, P = 0.02), target vessel MI (2.2% vs. 5.8%, P = 0.01), and definite/probable ST (0.3% vs. 2.2%, P = 0.04).
CONCLUSIONS: BuMA SES, with faster drug elution rate and polymer absorption kinetics, might improve safety outcomes compared to Excel SES in the high-risk AMI population.
© 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  acute myocardial infarction; biodegradable polymer; drug elution; drug-eluting stents; polymer absorption

Mesh:

Substances:

Year:  2017        PMID: 28109057     DOI: 10.1002/ccd.26918

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  2 in total

1.  Incidence and predictors of target lesion failure in patients undergoing contemporary DES implantation-Individual patient data pooled analysis from 6 randomized controlled trials.

Authors:  Maayan Konigstein; Mahesh V Madhavan; Ori Ben-Yehuda; Hussein M Rahim; Iva Srdanovic; Fotis Gkargkoulas; Ghazaleh Mehdipoor; Evan Shlofmitz; Akiko Maehara; Björn Redfors; Ankita K Gore; Thomas McAndrew; Gregg W Stone; Ziad A Ali
Journal:  Am Heart J       Date:  2019-04-12       Impact factor: 4.749

2.  Controlled organocatalyzed d,l-lactide ring-opening polymerizations: synthesis of low molecular weight oligomers.

Authors:  M R Newman; S G Russell; D S W Benoit
Journal:  RSC Adv       Date:  2018-08-14       Impact factor: 4.036

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.