Literature DB >> 28104922

Volumetric Doppler angle correction for ultrahigh-resolution optical coherence Doppler tomography.

Jiang You1, Ang Li1, Congwu Du1, Yingtian Pan1.   

Abstract

Ultrahigh-resolution optical coherence Doppler tomography (μODT) demonstrates great potential for quantitative blood flow imaging owing to its large field of view and capillary resolution. However, μODT only detects the axial flow velocity and requires Doppler angle correction to retrieve the absolute velocity. Although methods for Doppler angle tracking of single or few large vessels have been reported, a method that enables angle correction of the entire 3D microvascular networks remains a challenge. Here, we present a method based on eigenvalue analysis of 3D Hessian matrix to retrieve the orientation of each tubular vessel. As the algorithm is voxel based, it is suitable for effective tracking of Doppler angle matrix and restoring the absolute flow over the 3D vascular flow networks. We present results on simulation and flow phantom studies to show its efficacy for accurate 3D angle tracking and absolute flow correction. Then, we perform an in vivo validation study on mouse micro-circulatory cerebral blood flow (CBF) networks, which clearly demonstrates the capability of this method for tracking the Doppler angle matrix of the highly complex 3D CBF networks.

Entities:  

Year:  2017        PMID: 28104922      PMCID: PMC5218966          DOI: 10.1063/1.4973367

Source DB:  PubMed          Journal:  Appl Phys Lett        ISSN: 0003-6951            Impact factor:   3.791


  12 in total

1.  Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity.

Authors:  Y Zhao; Z Chen; C Saxer; S Xiang; J F de Boer; J S Nelson
Journal:  Opt Lett       Date:  2000-01-15       Impact factor: 3.776

2.  In vivo total retinal blood flow measurement by Fourier domain Doppler optical coherence tomography.

Authors:  Yimin Wang; Bradley A Bower; Joseph A Izatt; Ou Tan; David Huang
Journal:  J Biomed Opt       Date:  2007 Jul-Aug       Impact factor: 3.170

3.  Optical coherence tomography for the quantitative study of cerebrovascular physiology.

Authors:  Vivek J Srinivasan; Dmitriy N Atochin; Harsha Radhakrishnan; James Y Jiang; Svetlana Ruvinskaya; Weicheng Wu; Scott Barry; Alex E Cable; Cenk Ayata; Paul L Huang; David A Boas
Journal:  J Cereb Blood Flow Metab       Date:  2011-03-02       Impact factor: 6.200

4.  Orientation-independent rapid pulsatile flow measurement using dual-angle Doppler OCT.

Authors:  Lindsy M Peterson; Shi Gu; Michael W Jenkins; Andrew M Rollins
Journal:  Biomed Opt Express       Date:  2014-01-15       Impact factor: 3.732

5.  Quantitative imaging of microvascular blood flow networks in deep cortical layers by 1310 nm μODT.

Authors:  Jiang You; Qiujia Zhang; Kicheon Park; Congwu Du; Yingtian Pan
Journal:  Opt Lett       Date:  2015-09-15       Impact factor: 3.776

6.  Fully distributed absolute blood flow velocity measurement for middle cerebral arteries using Doppler optical coherence tomography.

Authors:  Li Qi; Jiang Zhu; Aneeka M Hancock; Cuixia Dai; Xuping Zhang; Ron D Frostig; Zhongping Chen
Journal:  Biomed Opt Express       Date:  2016-01-20       Impact factor: 3.732

7.  Segmentation and quantification of blood vessels for OCT-based micro-angiograms using hybrid shape/intensity compounding.

Authors:  Siavash Yousefi; Ting Liu; Ruikang K Wang
Journal:  Microvasc Res       Date:  2014-10-02       Impact factor: 3.514

8.  Ultrasensitive detection of 3D cerebral microvascular network dynamics in vivo.

Authors:  Yingtian Pan; Jiang You; Nora D Volkow; Kicheon Park; Congwu Du
Journal:  Neuroimage       Date:  2014-09-02       Impact factor: 6.556

9.  Total retinal blood flow measurement by three beam Doppler optical coherence tomography.

Authors:  Richard Haindl; Wolfgang Trasischker; Andreas Wartak; Bernhard Baumann; Michael Pircher; Christoph K Hitzenberger
Journal:  Biomed Opt Express       Date:  2016-01-06       Impact factor: 3.732

10.  Measurement of the total retinal blood flow using dual beam Fourier-domain Doppler optical coherence tomography with orthogonal detection planes.

Authors:  Veronika Doblhoff-Dier; Leopold Schmetterer; Walthard Vilser; Gerhard Garhöfer; Martin Gröschl; Rainer A Leitgeb; René M Werkmeister
Journal:  Biomed Opt Express       Date:  2014-01-28       Impact factor: 3.732

View more
  4 in total

1.  In vivo detection of tumor boundary using ultrahigh-resolution optical coherence angiography and fluorescence imaging.

Authors:  Jiang You; Chelsea Pan; Kicheon Park; Ang Li; Congwu Du
Journal:  J Biophotonics       Date:  2019-12-23       Impact factor: 3.207

2.  Polarization sensitive optical coherence tomography for imaging microvascular information within living tissue without polarization-induced artifacts.

Authors:  Peijun Tang; Ruikang K Wang
Journal:  Biomed Opt Express       Date:  2020-10-15       Impact factor: 3.732

3.  Long-term optical imaging of neurovascular coupling in mouse cortex using GCaMP6f and intrinsic hemodynamic signals.

Authors:  Xiaochun Gu; Wei Chen; Jiang You; Alan P Koretsky; N D Volkow; Yingtian Pan; Congwu Du
Journal:  Neuroimage       Date:  2017-09-30       Impact factor: 6.556

4.  A self-encapsulated broadband phototransistor based on a hybrid of graphene and black phosphorus nanosheets.

Authors:  Guigang Zhou; Zhongjun Li; Yanqi Ge; Han Zhang; Zhenhua Sun
Journal:  Nanoscale Adv       Date:  2019-12-20
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.