Literature DB >> 28103709

Radiation absorbed dose estimates for 18F-BPA PET.

Yuzuru Kono1, Hiroaki Kurihara1, Hiroshi Kawamoto2, Naoko Yasui2, Naoki Honda3, Hiroshi Igaki4, Jun Itami4.   

Abstract

Background Boron neutron capture therapy (BNCT) is a molecular radiation therapy approach based on the 10B (n, α) 7Li nuclear reaction in cancer cells. In BNCT, delivery of 10B in the form of 4-borono-phenylalanine conjugated with fructose (BPA-fr) to the cancer cells is important. The PET tracer 4-borono-2-18F-fluoro-phenylalanine (FBPA) has been used to predict the accumulation of BPA-fr before BNCT. Purpose To determine the biodistribution and dosimetric parameters in 18F-BPA PET/CT studies. Material and Methods Human biokinetic data were obtained during clinical 18F-BPA PET studies between February and June 2015 at one institution. Nine consecutive patients were studied prospectively. The internal radiation dose was calculated on the basis of radioactivity data from blood, urine, and normal tissue of the heart, liver, spleen, kidney, and other parts of the body at each time point using OLINDA/EXM1.1 program. We compared our calculations with published 18F-FDG data. Results Adult patients (3 men, 3 women; age range, 28-68 years) had significantly smaller absorbed doses than pediatric patients (3 patients; age range, 5-12 years) ( P = 0.003). The mean effective dose was 57% lower in adult patients compared with pediatric patients. Mean effective doses for 18F-BPA were 25% lower than those for 18F-FDG presented in International Commission of Radiation Protection (ICRP) publication 106. Conclusion We found significant differences in organ absorbed doses for 18F-BPA against those for 18F-FDG presented in ICRP publication 106. Mean effective doses for 18F-BPA were smaller than those for 18F-FDG in the publication by 0.5-38% (mean difference, 25%).

Entities:  

Keywords:  18F-BPA PET; Boron neutron capture therapy (BNCT); effective dose; radiation absorbed dose

Mesh:

Substances:

Year:  2017        PMID: 28103709     DOI: 10.1177/0284185116688378

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  2 in total

1.  A Novel Approach to Design and Evaluate BNCT Neutron Beams Combining Physical, Radiobiological, and Dosimetric Figures of Merit.

Authors:  Ian Postuma; Sara González; Maria S Herrera; Lucas Provenzano; Michele Ferrarini; Chiara Magni; Nicoletta Protti; Setareh Fatemi; Valerio Vercesi; Giuseppe Battistoni; Umberto Anselmi Tamburini; Yuan Hao Liu; Leena Kankaanranta; Hanna Koivunoro; Saverio Altieri; Silva Bortolussi
Journal:  Biology (Basel)       Date:  2021-02-26

2.  Boron neutron capture therapy of cancer: Critical issues and future prospects.

Authors:  Tai-Ze Yuan; Shu-Qing Xie; Chao-Nan Qian
Journal:  Thorac Cancer       Date:  2019-11-03       Impact factor: 3.500

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.