Literature DB >> 28102822

Successful Percutaneous Device Closure of Right Ventricular Perforation During Pericardiocentesis.

Anita Saxena1, Suman Karmakar1, Rajiv Narang2.   

Abstract

Keywords:  device closure; percutaneous intervention; pericardiocentesis

Mesh:

Year:  2016        PMID: 28102822     DOI: 10.1016/j.jcin.2016.09.031

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


× No keyword cloud information.
  4 in total

1.  Percutaneous suture based device closure of an inadvertent right ventricle perforation following pericardiocentesis.

Authors:  Rajesh Vijayvergiya; Yamasandi S Shrimanth; Ganesh Kasinadhuni; Harkant Singh; Ashish Sharma; Anish Bhargav; Navjyot Kaur
Journal:  Anatol J Cardiol       Date:  2021-11       Impact factor: 1.596

2.  Percutaneous Treatment of Right Ventricular Rupture with ADO II device via the Subxiphoid Pericardial Window; After Percutaneous Treatment of Cardiac Tamponade.

Authors:  Elnur Alizade; Cemalettin Yılmaz; İsmail Balaban; Zeki Şimşek; Mustafa Ferhat Keten
Journal:  Anatol J Cardiol       Date:  2021-05       Impact factor: 1.596

3.  Employing Amplatzer Occluder® in Cardiac Free Wall Rupture Repair: A Scoping Study.

Authors:  Pramod Theetha Kariyanna; Ashkan Tadayoni; Amog Jayarangaiah; Sudhanva Hegde; Apoorva Jayaranagaiah; Moro O Salifu; Isabel M McFarlane
Journal:  Am J Med Case Rep       Date:  2020-05-22

4.  Minimally invasive repair of iatrogenic right ventricular perforation guided by bedside contrast-enhanced ultrasound: A case report and literature review.

Authors:  Yanchun Zhao; Yucheng Lin; Zhiliang Hong; Baochun Lai; Lianghua Lian; Lin Chen; Qi Xie; Xiaofen Zhou; Songsong Wu
Journal:  Front Cardiovasc Med       Date:  2022-10-04