Literature DB >> 28102175

Markerless rat head motion tracking using structured light for brain PET imaging of unrestrained awake small animals.

Alan Miranda1, Steven Staelens, Sigrid Stroobants, Jeroen Verhaeghe.   

Abstract

Preclinical positron emission tomography (PET) imaging in small animals is generally performed under anesthesia to immobilize the animal during scanning. More recently, for rat brain PET studies, methods to perform scans of unrestrained awake rats are being developed in order to avoid the unwanted effects of anesthesia on the brain response. Here, we investigate the use of a projected structure stereo camera to track the motion of the rat head during the PET scan. The motion information is then used to correct the PET data. The stereo camera calculates a 3D point cloud representation of the scene and the tracking is performed by point cloud matching using the iterative closest point algorithm. The main advantage of the proposed motion tracking is that no intervention, e.g. for marker attachment, is needed. A manually moved microDerenzo phantom experiment and 3 awake rat [18F]FDG experiments were performed to evaluate the proposed tracking method. The tracking accuracy was 0.33 mm rms. After motion correction image reconstruction, the microDerenzo phantom was recovered albeit with some loss of resolution. The reconstructed FWHM of the 2.5 and 3 mm rods increased with 0.94 and 0.51 mm respectively in comparison with the motion-free case. In the rat experiments, the average tracking success rate was 64.7%. The correlation of relative brain regional [18F]FDG uptake between the anesthesia and awake scan reconstructions was increased from on average 0.291 (not significant) before correction to 0.909 (p  <  0.0001) after motion correction. Markerless motion tracking using structured light can be successfully used for tracking of the rat head for motion correction in awake rat PET scans.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28102175     DOI: 10.1088/1361-6560/aa5a46

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  2 in total

1.  Acute Ketamine Infusion in Rat Does Not Affect In Vivo [11C]ABP688 Binding to Metabotropic Glutamate Receptor Subtype 5.

Authors:  Lauren Kosten; Jeroen Verhaeghe; Leonie Wyffels; Sigrid Stroobants; Steven Staelens
Journal:  Mol Imaging       Date:  2018 Jan-Dec       Impact factor: 4.488

2.  Markerless motion tracking and correction for PET, MRI, and simultaneous PET/MRI.

Authors:  Jakob M Slipsager; Andreas H Ellegaard; Stefan L Glimberg; Rasmus R Paulsen; M Dylan Tisdall; Paul Wighton; André van der Kouwe; Lisbeth Marner; Otto M Henriksen; Ian Law; Oline V Olesen
Journal:  PLoS One       Date:  2019-04-19       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.