Literature DB >> 2809821

Treatment of subtrochanteric femur fractures using the dynamic condylar screw.

R Sanders1, P Regazzoni.   

Abstract

Thirty-two consecutive subtrochanteric femur fractures were treated using the 95 degree dynamic condylar screw between 1982 and 1985. All fractures were classified according to the radiographic criteria of Seinsheimer. Twenty-two patients were available for follow-up study, with an average time of 23.8 months. Functional results were rated using a new traumatic hip score rating system. The overall union rate was 77.3% (17/22), with functional results rated as excellent or good in 68% (15/22). All five technical failures were associated with extensive bony comminution. Four of these failures were not bone grafted. There were no cases of screw penetration of the femoral head or neck. The indications for the use of this device include transverse, short, and long oblique subtrochanteric fractures, with or without lesser trochanteric avulsion. When excessive comminution exists, this device should not be employed.

Entities:  

Mesh:

Year:  1989        PMID: 2809821     DOI: 10.1097/00005131-198909000-00005

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  6 in total

1.  Treatment of subtrochanteric fractures of the femur: reduction on the traction table and fixation with dynamic condylar screw.

Authors:  G Blatter; M Janssen
Journal:  Arch Orthop Trauma Surg       Date:  1994       Impact factor: 3.067

2.  Reversed distal femoral locking plate for failed proximal femoral nail with non-union of proximal femoral fractures.

Authors:  Raju Vaishya; Amit Kumar Agarwal; Nishint Gupta; Vipul Vijay
Journal:  Int Orthop       Date:  2015-10-09       Impact factor: 3.075

3.  Treatment of subtrochanteric femoral fractures using Selfdynamisable internal fixator.

Authors:  Ivan D Micic; Milorad B Mitkovic; Il-Hyung Park; Desimir B Mladenovic; Predrag M Stojiljkovic; Zoran B Golubovic; In-Ho Jeon
Journal:  Clin Orthop Surg       Date:  2010-11-05

4.  Comparison of cutout resistance of dynamic condylar screw and proximal femoral nail in reverse oblique trochanteric fractures: A biomechanical study.

Authors:  Gursimrat Singh Cheema; Amit Rastogi; Vakil Singh; Satish Chandra Goel; Diwakar Mishra; Sumit Arora
Journal:  Indian J Orthop       Date:  2012-05       Impact factor: 1.251

5.  Augmentation Plate Fixation for Treating Subtrochanteric Fracture Nonunion.

Authors:  Yu Cheng Lo; Yu Ping Su; Cheng Pu Hsieh; Chun Hsiung Huang
Journal:  Indian J Orthop       Date:  2019 Mar-Apr       Impact factor: 1.251

6.  Is Full-Length Intramedullary Nail Necessary for Atypical Subtrochanteric Femoral Fracture Associated with Bisphosphonate?

Authors:  Kwang-Kyoun Kim; Seung Kwon Ryu; Seok-Won Lee; Hyun-Jae Cha
Journal:  J Bone Metab       Date:  2020-05-31
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.