Literature DB >> 2809667

Intraoperative somatosensory evoked responses recorded during onset of the anterior spinal artery syndrome.

M H Zornow1, J C Drummond.   

Abstract

Somatosensory evoked responses may be used during operations on the thoracic aorta to monitor spinal cord function. A patient is described in whom the evoked responses were well maintained for the first 20 minutes of aortic occlusion and briskly returned to baseline configuration after reestablishment of aortic flow. Nonetheless, the patient was left with paralysis of the lower extremities consistent with the diagnosis of anterior spinal artery syndrome.

Entities:  

Mesh:

Year:  1989        PMID: 2809667     DOI: 10.1007/bf01618254

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  7 in total

1.  Somatosensory evoked potential monitoring of spinal cord ischemia during aortic operations.

Authors:  B J Kaplan; W A Friedman; J A Alexander; S R Hampson
Journal:  Neurosurgery       Date:  1986-07       Impact factor: 4.654

2.  Monitoring of somatosensory evoked potentials during surgical procedures on the thoracoabdominal aorta. IV. Clinical observations and results.

Authors:  J N Cunningham; J C Laschinger; F C Spencer
Journal:  J Thorac Cardiovasc Surg       Date:  1987-08       Impact factor: 5.209

3.  Monitoring of somatosensory evoked potentials during surgical procedures on the thoracoabdominal aorta. I. Relationship of aortic cross-clamp duration, changes in somatosensory evoked potentials, and incidence of neurologic dysfunction.

Authors:  J C Laschinger; J N Cunningham; M M Cooper; F G Baumann; F C Spencer
Journal:  J Thorac Cardiovasc Surg       Date:  1987-08       Impact factor: 5.209

4.  Measurement of spinal cord ischemia during operations upon the thoracic aorta: initial clinical experience.

Authors:  J N Cunningham; J C Laschinger; H A Merkin; I M Nathan; S Colvin; J Ransohoff; F C Spencer
Journal:  Ann Surg       Date:  1982-09       Impact factor: 12.969

5.  Somatosensory evoked potentials in the detection of spinal cord ischemia in aortic coarctation repair.

Authors:  J C Pollock; M P Jamieson; R McWilliam
Journal:  Ann Thorac Surg       Date:  1986-03       Impact factor: 4.330

6.  Spinal cord damage in surgery of the abdominal aorta.

Authors:  D E Szilagyi; J H Hageman; R F Smith; J P Elliott
Journal:  Surgery       Date:  1978-01       Impact factor: 3.982

7.  Somatosensory evoked potentials during reversible spinal cord ischemia in man.

Authors:  E M Mizrahi; E S Crawford
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1984-08
  7 in total
  1 in total

1.  Spinal cord ischemia and motor evoked potentials.

Authors:  D J Doyle
Journal:  J Clin Monit       Date:  1990-10
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.