Literature DB >> 28094423

Repeatability and accuracy testing of a weight distribution platform and comparison to a pressure sensitive walkway to assess static weight distribution.

Georgia Bosscher, Andrea Tomas, Simon C Roe1, Denis J Marcellin-Little, B Duncan X Lascelles.   

Abstract

OBJECTIVE: To evaluate the accuracy and repeatability of measurements collected using a weight distribution platform and a pressure sensitive walkway using an inanimate object with known weight distribution.
METHODS: A custom-built jig with a range of weights was applied in a random order. Measurements were collected on both devices and compared to each other and to the known weight distribution.
RESULTS: Weight distribution platform and pressure sensitive walkway measurements were highly correlated to each other (Pearson's correlation coefficient R = 0.98) and to actual weights (R = 0.99 for the weight distribution platform; 0.98 for the pressure sensitive walkway). Repeatability from day to day for both devices was greater than 0.99. For the weight distribution platform, the 95% confidence interval was ± 2.5% from the true percentage and ± 3.3% for the pressure sensitive walkway. The coefficient of variation (COV) was highest for both devices at the lightest weights (weight distribution platform 11.28%, pressure sensitive walkway 16.91%) and lowest with the heaviest weights (weight distribution platform 3.71%, pressure sensitive walkway 5.86%).
CONCLUSION: Both the weight distribution platform and the pressure sensitive walkway provided accurate and consistent measures of weight distribution with no significant difference between devices. The rounded standard error was three percent for the weight distribution platform, and four percent for the pressure sensitive walkway. The higher variability when measuring the smallest weight suggests less accuracy at lower weights with both devices. CLINICAL SIGNIFICANCE: The weight distribution platform is a repeatable and accessible device to measure static weight distribution, and if proven the same in a clinical setting, it will be a valuable addition to current objective measures of limb use.

Keywords:  Pressure sensitive walkway; repeatability; static weight distribution; weight distribution platform

Mesh:

Year:  2017        PMID: 28094423     DOI: 10.3415/VCOT-16-09-0128

Source DB:  PubMed          Journal:  Vet Comp Orthop Traumatol        ISSN: 0932-0814            Impact factor:   1.358


  3 in total

1.  Stance and weight distribution after tibial plateau leveling osteotomy in fore limb and hind limb amputee dogs.

Authors:  Ron Ben-Amotz; David Dycus; David Levine; Andréia Gonçalves Arruda; Nicholas Fagan; Denis Marcellin-Little
Journal:  BMC Vet Res       Date:  2020-06-10       Impact factor: 2.741

2.  Clinical and diagnostic imaging findings in police working dogs referred for hip osteoarthritis.

Authors:  J C Alves; A Santos; P Jorge; C Lavrador; L Miguel Carreira
Journal:  BMC Vet Res       Date:  2020-11-07       Impact factor: 2.741

3.  Comparison of clinical and radiographic signs of hip osteoarthritis in contralateral hip joints of fifty working dogs.

Authors:  J C Alves; Ana Santos; Patrícia Jorge; Catarina Lavrador; L Miguel Carreira
Journal:  PLoS One       Date:  2021-03-18       Impact factor: 3.752

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.