Literature DB >> 28093860

Monolithic implant-supported lithium disilicate (LS2) crowns in a complete digital workflow: A prospective clinical trial with a 2-year follow-up.

Tim Joda1, Marco Ferrari2, Urs Brägger3.   

Abstract

BACKGROUND: The technical development of digital processing allows the production of anatomically full-contoured implant-supported restorations.
PURPOSE: The aim of this prospective clinical trial was to analyze the treatment concept of monolithic lithium disilicate (LS2) single-unit restorations in a complete digital workflow.
MATERIAL AND METHODS: Forty-four patients were restored with 50 screw-retained monolithic implant LS2 crowns bonded to pre-fabricated titanium abutments on soft tissue level implants (Institut Straumann AG, Basel, Switzerland) in premolar and molar sites. All implant restorations were digitally designed after intraoral optical scanning (IOS) and CAD/CAM-processing without physical model situations. Study participants were clinically and radiographically examined based on an annually performed follow-up. The "Functional Implant Prosthodontic Score" (FIPS) was applied for objective outcome assessment after 2 years of loading. Five variables were defined for FIPS evaluation, resulting in a maximum score of 10 per implant restoration. Descriptive statistics were calculated for mean scores standard deviations, medians, and Q25 -Q75 .
RESULTS: All patients could be successfully treated within two clinical appointments. No clinical modifications were necessary for the seating of the monolithic crowns, neither for interproximal nor occlusal sites. The implant LS2 restorations demonstrated survival rates of 100% without any technical or biological complications after 2 years. The mean total FIPS score was 7.7 ± 1.0, ranging from 6 to 10.
CONCLUSIONS: CAD/CAM-produced monolithic implant crowns out of LS2 in a complete digital workflow seem to be a feasible treatment concept for the rehabilitation of single-tooth gaps in posterior sites under mid-term observation.
© 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  computer-aided design (CAD); dental crowns; dental implants; intraoral scan (IOS); prosthodontics

Mesh:

Substances:

Year:  2017        PMID: 28093860     DOI: 10.1111/cid.12472

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  14 in total

1.  The Functional Implant Prosthodontic Score (FIPS): assessment of reproducibility and observer variability.

Authors:  Tim Joda; Fernando Zarone; Nicola U Zitzmann; Marco Ferrari
Journal:  Clin Oral Investig       Date:  2018-01-03       Impact factor: 3.573

2.  Digital intraoral scanner devices: a validation study based on common evaluation criteria.

Authors:  Ivett Róth; Alexandra Czigola; Dóra Fehér; Viktória Vitai; Gellért Levente Joós-Kovács; Péter Hermann; Judit Borbély; Bálint Vecsei
Journal:  BMC Oral Health       Date:  2022-04-26       Impact factor: 3.747

3.  Digital versus Analog Procedures for the Prosthetic Restoration of Single Implants: A Randomized Controlled Trial with 1 Year of Follow-Up.

Authors:  Francesco Mangano; Giovanni Veronesi
Journal:  Biomed Res Int       Date:  2018-07-18       Impact factor: 3.411

4.  Impact of Aging on the Accuracy of 3D-Printed Dental Models: An In Vitro Investigation.

Authors:  Tim Joda; Lea Matthisson; Nicola U Zitzmann
Journal:  J Clin Med       Date:  2020-05-12       Impact factor: 4.241

5.  A Novel Full-Digital Protocol (SCAN-PLAN-MAKE-DONE®) for the Design and Fabrication of Implant-Supported Monolithic Translucent Zirconia Crowns Cemented on Customized Hybrid Abutments: A Retrospective Clinical Study on 25 Patients.

Authors:  Francesco Mangano; Bidzina Margiani; Oleg Admakin
Journal:  Int J Environ Res Public Health       Date:  2019-01-24       Impact factor: 3.390

6.  Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study.

Authors:  Francesco Guido Mangano; Uli Hauschild; Giovanni Veronesi; Mario Imburgia; Carlo Mangano; Oleg Admakin
Journal:  BMC Oral Health       Date:  2019-06-06       Impact factor: 2.757

Review 7.  Current status on lithium disilicate and zirconia: a narrative review.

Authors:  Fernando Zarone; Maria Irene Di Mauro; Pietro Ausiello; Gennaro Ruggiero; Roberto Sorrentino
Journal:  BMC Oral Health       Date:  2019-07-04       Impact factor: 2.757

8.  A pilot trial on lithium disilicate partial crowns using a novel prosthodontic functional index for teeth (FIT).

Authors:  Edoardo Ferrari Cagidiaco; Simone Grandini; Cecilia Goracci; Tim Joda
Journal:  BMC Oral Health       Date:  2019-12-09       Impact factor: 2.757

Review 9.  The direct digital workflow in fixed implant prosthodontics: a narrative review.

Authors:  George Michelinakis; Dimitrios Apostolakis; Phophi Kamposiora; George Papavasiliou; Mutlu Özcan
Journal:  BMC Oral Health       Date:  2021-01-21       Impact factor: 2.757

Review 10.  Ceramic Materials and Technologies Applied to Digital Works in Implant-Supported Restorative Dentistry.

Authors:  Se-Wook Pyo; Dae-Joon Kim; Jung-Suk Han; In-Sung Luke Yeo
Journal:  Materials (Basel)       Date:  2020-04-22       Impact factor: 3.623

View more