| Literature DB >> 2809229 |
K Fujii1, M Tsuji, K Murota, K Terato, Y Shimozuru, Y Nagai.
Abstract
An improved enzyme-linked immunosorbent assay (ELISA) for the determination of anti-collagen antibodies in human serum has been developed. The method is based on the use of serum samples diluted to 1/50 with heat-inactivated normal rabbit serum adjusted to pH 8.0 with solid Tris (0.05 M), NaCl (0.15 M) and 2 M HCl. The use of normal rabbit serum minimizes non-specific adsorption of immunoglobulin G onto the plastic surface of microtiter plate. The applicability of the method for the quantitation of anti-collagen antibodies in human serum is demonstrated with 290 specimens of sera from normal controls (194) and patients with rheumatoid arthritis (96).Entities:
Mesh:
Substances:
Year: 1989 PMID: 2809229 DOI: 10.1016/0022-1759(89)90186-5
Source DB: PubMed Journal: J Immunol Methods ISSN: 0022-1759 Impact factor: 2.303