Literature DB >> 28088411

Standardization of milk infrared spectra for the retroactive application of calibration models.

V Bonfatti1, A Fleming2, A Koeck2, F Miglior3.   

Abstract

The objective of this study was to standardize the infrared spectra obtained over time and across 2 milk laboratories of Canada to create a uniform historical database and allow (1) the retroactive application of calibration models for prediction of fine milk composition; and (2) the direct use of spectral information for the development of indicators of animal health and efficiency. Spectral variation across laboratories and over time was inspected by principal components analysis (PCA). Shifts in the PCA scores were detected over time, leading to the definition of different subsets of spectra having homogeneous infrared signal. To evaluate the possibility of using common equations on spectra collected by the 2 instruments and over time, we developed a standardization (STD) method. For each subset of data having homogeneous infrared signal, a total of 99 spectra corresponding to the percentiles of the distribution of the absorbance at each wavenumber were created and used to build the STD matrices. Equations predicting contents of saturated fatty acids, short-chain fatty acids, and C18:0 were created and applied on different subsets of spectra, before and after STD. After STD, bias and root mean squared error of prediction decreased by 66% and 32%, respectively. When calibration equations were applied to the historical nonstandardized database of spectra, shifts in the predictions could be observed over time for all investigated traits. Shifts in the distribution of the predictions over time corresponded to the shifts identified by the inspection of the PCA scores. After STD, shifts in the predicted fatty acid contents were greatly reduced. Standardization reduced spectral variability between instruments and over time, allowing the merging of milk spectra data from different instruments into a common database, the retroactive use of calibrations equations, or the direct use of the spectral data without restrictions.
Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  infrared spectra; retroactive calibration models; standardization

Mesh:

Substances:

Year:  2017        PMID: 28088411     DOI: 10.3168/jds.2016-11837

Source DB:  PubMed          Journal:  J Dairy Sci        ISSN: 0022-0302            Impact factor:   4.034


  3 in total

1.  Mid-infrared (MIR) spectroscopy for the detection of cow's milk in buffalo milk.

Authors:  Anna Antonella Spina; Carlotta Ceniti; Cristian Piras; Bruno Tilocca; Domenico Britti; Valeria Maria Morittu
Journal:  J Anim Sci Technol       Date:  2022-05-31

2.  Genome-wide association analysis for β-hydroxybutyrate concentration in Milk in Holstein dairy cattle.

Authors:  S Nayeri; F Schenkel; A Fleming; V Kroezen; M Sargolzaei; C Baes; A Cánovas; J Squires; F Miglior
Journal:  BMC Genet       Date:  2019-07-16       Impact factor: 2.797

Review 3.  The evolving role of Fourier-transform mid-infrared spectroscopy in genetic improvement of dairy cattle.

Authors:  K M Tiplady; T J Lopdell; M D Littlejohn; D J Garrick
Journal:  J Anim Sci Biotechnol       Date:  2020-04-17
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.